MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mat.0000000000002737

Медицинская библиотека · ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2026

Pressure-Volume-Derived Ventricular Energetics Across Mechanical Circulatory Support Strategies in Cardiogenic Shock.

Ortega-Hernández Jorge A, Baldetti Luca, Gallone Guglielmo, Cacioli Giulio, Bocchino Pier Paolo, González-Pacheco Héctor, Amezcua-Guerra Luis, Festi Mariagiulia, Pirone Francesca, Calvo Francesco, Sacchi Stefania, Pieri Marina, Ajello Silvia, Frea Simone, Pasquero Marta, Sbaraglia Fabio, De Ferrari Gaetano Maria, Luzi Giampaolo, Springall Rashidi, Loforte Antonio, Hernández-Montfort Jaime, Scandroglio Anna Mara, Arias-Mendoza Alexandra

СтатьяПеревод в очереди

Аннотация

Bedside pressure-flow variables in cardiogenic shock (CS) incompletely characterize ventricular energetics and coupling. We prospectively derived bedside pressure-volume (PV) loop surrogates from paired pulmonary artery catheter and echocardiographic data in 68 patients (263 paired assessments) with acute myocardial infarction-related CS (AMI-CS) or heart failure-related CS (HF-CS) during microaxial support, intra-aortic balloon pump (IABP) support, or medical therapy. In AMI-CS with microaxial support, arterial elastance decreased (-1.22 mm Hg/ml) with improved coupling (ventriculoarterial coupling [VAC] -1.42), stroke work increased (+140 mm Hg·ml), and pressure-volume area declined (PVA -103 mm Hg·ml), yielding an efficiency rise from ~32% to ~40%, suggesting unloading. In HF-CS, microaxial support reduced elastance modestly (-0.35) with probable efficiency gain (+5%) but heterogeneous PVA changes. In AMI-CS treated with IABP, coupling improved (VAC -0.42) with modest energetic augmentation, whereas HF-CS showed pressure and energy amplification (end-systolic pressure +23.9 mm Hg; PVA +220.6 mm Hg ·ml). Without mechanical support, AMI-CS demonstrated reduced elastance and pressure, while HF-CS exhibited ventricular dilation (end-diastolic volume [EDV]/end-systolic volume ESV increase) with higher energetic demand. Pressure-volume-derived metrics identify device-specific energetic signatures not fully captured by conventional hemodynamic assessment and may provide mechanistic insight into ventricular unloading strategies; validation against conductance catheter-derived PV measurements remains warranted.

Для цитирования: Ortega-Hernández Jorge A, Baldetti Luca, Gallone Guglielmo, Cacioli Giulio, Bocchino Pier Paolo, González-Pacheco Héctor, Amezcua-Guerra Luis, Festi Mariagiulia, Pirone Francesca, Calvo Francesco, Sacchi Stefania, Pieri Marina, Ajello Silvia, Frea Simone, Pasquero Marta, Sbaraglia Fabio, De Ferrari Gaetano Maria, Luzi Giampaolo, Springall Rashidi, Loforte Antonio, Hernández-Montfort Jaime, Scandroglio Anna Mara, Arias-Mendoza Alexandra. Pressure-Volume-Derived Ventricular Energetics Across Mechanical Circulatory Support Strategies in Cardiogenic Shock.. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2026. DOI: 10.1097/mat.0000000000002737.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.