A rapid, simple and sensitive method for the determination and bioequivalence study of transdermal fentanyl in human plasma using liquid chromatography-electrospray ionization tandem mass spectrometry.
Аннотация
OBJECTIVE
Since the 1960s, fentanyl has been used to replace morphine nd other opioids due to its higher potency in the treatment of acute pain; since the 1990s, it has also been administrated to control chronic pain by using transdermal fentanyl device system. It is crucial and of utmost importance and crucial to validate a sensitive method for the quantification of transdermal fentanyl in human plasma.
MATERIALS AND
METHODS
A rapid, simple and sensitive high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method has been established and validated for the determination of transdermal fentanyl in human plasma using fentanyl-D5 as an internal standard (IS). Following liquid-liquid extraction (LLE) with n-hexane, the extracts were separated on a Thermo Hypersil ODS(C18) column (2.1 × 150 mm i.d., 5 μm) interfaced with a triple-quadrupole tandem mass spectrometer using positive electrospray ionization.
RESULTS AND
CONCLUSIONS
Quantification of fentanyl was carried out by multiple reaction monitoring (MRM) of the transitions at m/z 337.1→188.0 for fentanyl and 341.9→187.9 for IS. The lower limit of quantification was 9.75 pg×mL-1, and the test showed a linear range of 9.75 - 10,000 pg×mL-1. The validated method was subsequently applied to a bioequivalence (BE) study in 24 healthy Chinese volunteers by using transdermal fentanyl patches.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.