MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2024.06.012

Медицинская библиотека · The Annals of thoracic surgery · 2024

The Use of the CardioCel 3D 60° Patch for Aortic Arch Reconstruction in Infancy-A Word of Caution.

Venna Alyssia, Öztürk Mahmut, Reitz Justus, Park In Hye, Hanabergh Sofia, Selcuk Arif, Tongut Aybala, Desai Manan, d'Udekem Yves, Yerebakan Can

СтатьяПеревод в очереди

Аннотация

BACKGROUND

There are limited data on outcomes after implantation of the CardioCel 3D 60° patch in great vessel repair. After anecdotally witnessing an increase in negative outcomes, we reviewed our experience using this patch in our neonate and infant patients undergoing aortic arch repair.

METHODS

Aortic arch repair with implantation of the CardioCel 3D 60° patch was performed in 24 patients between July 2018 and July 2021. Dominant cardiac morphologies were hypoplastic left heart syndrome (66%), atrioventricular canal defects (13%), and other (21%). Median age at implantation was 44 days (interquartile range [IQR], 6-112 days). Recurrent obstruction was defined as the need for reoperation or catheter intervention or recurrent peak pressure gradient of descending aorta ≥25 mm Hg on echocardiography.

RESULTS

Five deaths occurred after a median of 217 days (IQR, 69-239 days). Twelve patients (50%) had recurrent obstruction. Three patients (13%) required redo aortic arch operation after a median of 148 days (IQR, 128-193 day), with extensive fibrous coating of the patch interior causing obstruction. Eleven patients (46%) required at least 1 balloon angioplasty on their aorta after a median of 102 days (IQR, 83-130 days) after repair, and 3 needed >1 catheter intervention. The estimated probability of having recurrent obstruction was 85% at 6 months and 71% at the 1-year follow (P = .06).

CONCLUSIONS

Recurrent aortic obstruction occurred in half of our patients shortly after repair. The use of the CardioCel 3D 60° patch for aortic arch reconstruction in neonates and infants should be reevaluated.

Для цитирования: Venna Alyssia, Öztürk Mahmut, Reitz Justus, Park In Hye, Hanabergh Sofia, Selcuk Arif, Tongut Aybala, Desai Manan, d'Udekem Yves, Yerebakan Can. The Use of the CardioCel 3D 60° Patch for Aortic Arch Reconstruction in Infancy-A Word of Caution.. The Annals of thoracic surgery. 2024. DOI: 10.1016/j.athoracsur.2024.06.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.