MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jcla.20282

Медицинская библиотека · Journal of clinical laboratory analysis · 2009

Comparison of PCR methods for detecting fetal RhDin maternal plasma.

Atamaniuk Johanna, Stuhlmeier Karl M, Karimi Alireza, Mueller Mathias M

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Aim of this study was to establish the method yielding the highest sensitivity routinely used to determine fetal RhD type and gender from maternal cell-free plasma DNA in different periods of gestation.

METHODS

Plasma DNA concentrations were measured from 46 pregnant women in different gestational periods and tested for RhD using three different PCR methods on exon 7: Thermal Cycler, Taqman method on LightCycler, and melting curve analysis on LightCycler. In addition, fetal gender was determined by PCR. Cell-free plasma DNA was measured in 100 healthy volunteers as a reference group.

RESULTS

The mean value of cell-free plasma DNA in the reference group was 10.9 pg/microL mean, (standard deviation (SD): 3.66) in 50 healthy women and 12.7 pg/microL (SD: 8.2) in 50 healthy men. In the first trimester of pregnancy cell-free plasma DNA was 14.9 pg/microL mean, (SD: 4.2), in the second trimester 15.4 pg/microL mean, (SD: 4.96), and the maximum was achieved in the third trimester of pregnancy 15.6 pg/microl mean, (SD: 6.49). TaqMan probes had the same accuracy, when compared with Thermal Cycler technology (46 samples, 6 failures). Using real-time PCR with melting curve analysis 12 of 17 samples were correctly tested. Gender determination was correctly in 41 of 46 samples.

CONCLUSION

RhD determinations with TaqMan and Thermal Cycler technology are useful methods for fetal RhD prediction. To increase the accuracy of RhD determination it is necessary to test on other exons in addition.

Для цитирования: Atamaniuk Johanna, Stuhlmeier Karl M, Karimi Alireza, Mueller Mathias M. Comparison of PCR methods for detecting fetal RhDin maternal plasma.. Journal of clinical laboratory analysis. 2009. DOI: 10.1002/jcla.20282.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.