m+Medelevator.RU
← Поиск публикаций
Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association · 2013

Ultrasound elastography of the liver, spleen, and kidneys in clinically normal cats.

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

White Jennifer, Gay John, Farnsworth Raelynn, Mickas Matt, Kim KwangGi, Mattoon John

Аннотация

A large amount of overlap exists in the B-mode ultrasound appearance of normal and abnormal liver, spleen, and kidney tissues in cats. Therefore, invasive tissue sampling procedures remain the standard method for diagnosing diseases in these organs. The purpose of our study was to assess the feasibility of ultrasound elastography as a technique for improving noninvasive characterization of the feline liver, spleen, and kidneys. Elastography was performed on 10 unsedated, clinically healthy cats. Numeric (strain) values (0 = softest to 255 = firmest) assigned to color pixels within regions of interest resulted in median scores (interquartile ranges) of body wall, 207.50 (189.75-224.00); liver, 119.00 (105.00-138.25); spleen, 127.50 (121-00-142.00); right renal cortex, 83.50 (64.00-130.00); right renal near field, 125.50 (110.75-139.75); left renal cortex, 77.50 (52.00-116.25); and left renal near field, 126.00 (114.00-145.25). Strain values were not different between organs. Body wall median was the only significantly different value (P < 0.05). Strain ratio values of body wall:organ were as follows: liver, 1.76 (1.38-2.00); spleen, 1.68 (1.47-1.83); right renal cortex, 2.31 (1.61-3.15); right renal near field, 1.62 (1.41-2.01); left renal cortex, 2.66 (1.45-4.13); and left renal near field, 1.51 (1.29-1.89). Subjectively, hepatic and splenic parenchymal tissues were homogeneous in compressibility and similar in elasticity to one another. Renal cortical tissue was softer compared to medullary tissue. Findings indicated that ultrasound elastography is a feasible technique for objectively and subjectively characterizing the feline liver, spleen, and kidneys. Further research is needed in cats with confirmed diseases of these organs, to compare the diagnostic sensitivity of ultrasound elastography vs. B-mode ultrasonography.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты