MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1667/rade-20-00167.1

Медицинская библиотека · Radiation research · 2021

Feasibility Study on Automatic Interpretation of Radiation Dose Using Deep Learning Technique for Dicentric Chromosome Assay.

Jang Seungsoo, Shin Sung-Gyun, Lee Min-Jae, Han Sangsoo, Choi Chan-Ho, Kim Sungkyum, Cho Woo-Sung, Kim Song-Hyun, Kang Yeong-Rok, Jo Wolsoon, Jeong Sookyung, Oh Sujung

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The interpretation of radiation dose is an important procedure for both radiological operators and persons who are exposed to background or artificial radiations. Dicentric chromosome assay (DCA) is one of the representative methods of dose estimation that discriminates the aberration in chromosomes modified by radiation. Despite the DCA-based automated radiation dose estimation methods proposed in previous studies, there are still limitations to the accuracy of dose estimation. In this study, a DCA-based automated dose estimation system using deep learning methods is proposed. The system is comprised of three stages. In the first stage, a classifier based on a deep learning technique is used for filtering the chromosome images that are not appropriate for use in distinguishing the chromosome; 99% filtering accuracy was achieved with 2,040 test images. In the second stage, the dicentric rate is evaluated by counting and identifying chromosomes based on the Feature Pyramid Network, which is one of the object detection algorithms based on deep learning architecture. The accuracies of the neural networks for counting and identifying chromosomes were estimated at over 97% and 90%, respectively. In the third stage, dose estimation is conducted using the dicentric rate and the dose-response curve. The accuracies of the system were estimated using two independent samples; absorbed doses ranging from 1- 4 Gy agreed well within a 99% confidential interval showing highest accuracy compared to those in previous studies. The goal of this study was to provide insights towards achieving complete automation of the radiation dose estimation, especially in the event of a large-scale radiation exposure incident.

Для цитирования: Jang Seungsoo, Shin Sung-Gyun, Lee Min-Jae, Han Sangsoo, Choi Chan-Ho, Kim Sungkyum, Cho Woo-Sung, Kim Song-Hyun, Kang Yeong-Rok, Jo Wolsoon, Jeong Sookyung, Oh Sujung. Feasibility Study on Automatic Interpretation of Radiation Dose Using Deep Learning Technique for Dicentric Chromosome Assay.. Radiation research. 2021. DOI: 10.1667/rade-20-00167.1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.