MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jocmr.2025.101989

Медицинская библиотека · Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2025

Improved accuracy for myocardial blood flow mapping with deep learning-enabled CMR arterial spin labeling (DeepMASL): Validation by microsphere in vivo.

Li Ran, Berberet Caleb, Huang Qi, Woodard Pamela K, Zheng Jie

СтатьяВалидационное исследованиеПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

BACKGROUND

Current myocardial arterial spin labeling (ASL) methods are sensitive to noise (background and physiology), which limits the accuracy of myocardial blood flow (MBF) measurement. In this study, we demonstrated a new deep learning-enabled myocardial ASL approach (DeepMASL) and evaluated its accuracy to quantify MBF in a canine model of coronary arterial disease in vivo. The reference method was invasive microsphere measurements.

METHODS

Eighteen mongrel dogs were divided into two groups: healthy (n = 9) and coronary stenosis (n = 9). The latter was induced in an open-chest model with 3 types of stenosis: 50% (n= 3), 70% (n = 3), and 90% (n = 3). Each dog received pharmaceutically induced hyperemia, by the infusion of either dipyridamole or dobutamine to induce different levels of MBF. Microsphere measurements were performed at rest and during the hyperemia. A cardiac ASL sequence was employed to acquire ASL signals at the mid-section of the heart, at rest and during the hyperemia. A physics-based deep learning network (DeepMASL) was developed using synthetic ASL signals with different levels of background noise. Segmented MBF values produced by both non-DeepMASL and DeepMASL methods were measured in all dogs to compare with segmented microsphere MBF values.

RESULTS

While the non-DeepMASL method severely underestimated hyperemic MBF by 33-49%, the DeepMASL approach dramatically improved the accuracy to obtain error less than 10%. There were strong correlations (r = 0.85 - 0.86) in segmented MBF values between measurements by DeepMASL and microsphere methods in either normal or ischemic dogs with varying degrees of coronary artery stenosis. The Bland-Altman analysis revealed mild to moderate variations of DeepMASL (95% confident interval: -1.3 to 1.5 ml/min/g in normal dogs and -1.8 to 1.3 ml/min/g in stenotic dogs) and almost zero bias.

CONCLUSION

The novel DeepMASL demonstrates much improved accuracy in the quantification of regional MBF at varying levels of coronary artery stenosis, which is correlated strongly with microsphere MBF values. The validated data indicates the potential for this DeepMASL technique to be translated for noncontrast diagnosis of myocardial perfusion deficit in a clinical setting.

Для цитирования: Li Ran, Berberet Caleb, Huang Qi, Woodard Pamela K, Zheng Jie. Improved accuracy for myocardial blood flow mapping with deep learning-enabled CMR arterial spin labeling (DeepMASL): Validation by microsphere in vivo.. Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance. 2025. DOI: 10.1016/j.jocmr.2025.101989.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.