MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2025.08.010

Медицинская библиотека · Heart rhythm · 2025

High incidence of phrenic nerve injury in patients undergoing pulsed field ablation for atrial fibrillation.

Chéhirlian Louis, Koutbi Linda, Mancini Julien, Hourdain Jérôme, Richard-Vitton Robin, Wilkin Marie, Deharo Jean-Claude, Maille Baptiste, Franceschi Frédéric

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Pulsed field ablation (PFA) is thought to reduce the risk of phrenic nerve injury (PNI) during atrial fibrillation (AF) ablation because of its myocardial selectivity. However, several reports suggest PNI still occurs.

OBJECTIVE

This study aimed to evaluate the incidence and characteristics of PNI during PFA using sequential compound motor action potential (CMAP) monitoring and assess diaphragmatic function at discharge.

METHODS

This prospective study included 64 consecutive patients undergoing PFA for AF. Right phrenic nerve function was monitored using CMAP during ablation. A baseline amplitude was measured before right pulmonary vein ablation, and subsequently monitored sequentially throughout the procedure. In case of intra-procedural PNI, all patients underwent a chest X-ray, and the last 25 also had a fluoroscopic loop the following day.

RESULTS

PNI occurred in 26 patients (40.6%). Incomplete recovery was observed in 12 (18.8%) at the end of the procedure. Chest X-rays were normal in all cases. Among the last 25 patients, 12 experienced intra-procedural PNI and underwent fluoroscopic assessment at discharge, of whom 6 patients (50%) had persistent incomplete PNI. The overall incidence of PNI at discharge was 24% (6/25). Follow-up fluoroscopy confirmed recovery in 4 of 5 patients reassessed, while 1 showed persistent dysfunction at 3 months.

CONCLUSION

PNI is a frequent complication of PFA. Incomplete paralysis is commonly observed at the end of the procedure. Fluoroscopy enables diagnosis of incomplete PNI at discharge, which remains a frequent finding. One patient showed persistent dysfunction at 3 months.

Для цитирования: Chéhirlian Louis, Koutbi Linda, Mancini Julien, Hourdain Jérôme, Richard-Vitton Robin, Wilkin Marie, Deharo Jean-Claude, Maille Baptiste, Franceschi Frédéric. High incidence of phrenic nerve injury in patients undergoing pulsed field ablation for atrial fibrillation.. Heart rhythm. 2025. DOI: 10.1016/j.hrthm.2025.08.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.