DOI 10.1016/j.jmig.2016.10.008
Assessment of Synthetic Glue for Mesh Attachment in Laparoscopic Sacrocolpopexy: A Prospective Multicenter Pilot Study.
Аннотация
STUDY
OBJECTIVE
To assess the anatomic efficacy and safety of synthetic glue to fix prosthetic material in laparoscopic sacrocolpopexy.
DESIGN
A 1-year follow-up in a prospective multicenter pilot study between November 2013 and November 2014 (Canadian Task Force Classification II-2).
SETTING
An academic urogynecology research hospital.
PATIENTS: Seventy consecutive patients with Pelvic Organ Prolapse Quantification stage ≥3 anterior and/or medial prolapse underwent laparoscopic sacrocolpopexy.
INTERVENTIONS: All women underwent laparoscopic sacrocolpopexy with the same standardized technique using a synthetic surgical glue to fix anterior and posterior meshes.
MEASUREMENTS AND MAIN
RESULTS
Patients were followed up at 1 month and 1 year, with anatomic and functional assessment (Pelvic Floor Distress Inventory-20, Pelvic Floor Impact Questionnaire-7, and Pelvic Organ Prolapse/Urinary Incontinence Sexual Questionnaire-12). Anatomic success was defined as 1-year Pelvic Organ Prolapse Quantification stage ≤1. Sixty-six patients were included; the mean age was 56.7 ± 1.2 years. The mean operative time was 145 ± 5 minutes. The mean glue fixation time was less than 2 minutes for both anterior and posterior meshes. The 1-year anatomic success rate was 87.5% in the anterior compartment (Ba at -2.3 cm, p < .0001) and 95.3% in the medial compartment (point C at -6.1 cm, p < .0001). There were no intra- or postoperative complications and no cases of mesh exposure; 5 cases of mesh shrinkage (7.8%) were observed at 1 year. The postoperative urinary stress incontinence rate was 29.7% at 1 year. Eight patients (12.1%) underwent revision surgery with transobturator tape. All quality of life scores showed significant improvement (p < .0001) at 1 year.
CONCLUSION
Synthetic glue attachment of prosthetic material in laparoscopic sacrocolpopexy proved straightforward, safe, time-saving, and effective at 1 year. Prospective randomized studies will be needed to confirm the long-term benefit.