Microincision versus small-incision coaxial cataract surgery using different power modes for hard nuclear cataract.

Kim Eun Chul, Byun Yong Soo, Kim Man Soo

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

PURPOSE: To compare the efficacy of microincision and small-incision coaxial phacoemulsification in treating hard cataracts using different ultrasound power modes.

SETTING

Department of Ophthalmology, Seoul St. Mary's Hospital, College of Medicine, Catholic University of Korea, Seoul, Korea.

DESIGN

Randomized clinical trial.

METHODS

Eyes with hard cataract were randomized to have an initial incision of 1.80 mm, 2.20 mm, or 2.75 mm. The eyes in each group were equally randomized to treatment with burst, pulse, or continuous mode. Ultrasound time (UST), mean cumulative dissipated energy (CDE), corrected distance visual acuity (CDVA), surgically induced corneal astigmatism, incisional and central corneal thickness (CCT), and endothelial cell counts were evaluated.

RESULTS

The study enrolled 180 eyes, 60 in each group. Two months postoperatively, there were no statistically significant differences in UST, CDE, CDVA, CCT, or percentage endothelial cell loss between the 3 incision groups. The 2.75 mm incision induced more astigmatism at 2 months and less incisional corneal edema at 1 week than the 1.80 mm or 2.20 mm incision (P<.05). The UST, CDE, incisional corneal thickness, and CCT at 1 week and the percentage endothelial cell loss at 2 months with continuous mode were statistically significantly higher than with pulse mode and burst mode in all 3 incision groups (P<.05).

CONCLUSIONS

Phacoemulsification using microincisions may be as safe and effective as the conventional small incision for hard cataract. The intraoperative energy use and ocular damage was less with the pulse and burst modes than with the continuous mode.

FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.

Для цитирования: Kim Eun Chul, Byun Yong Soo, Kim Man Soo. Microincision versus small-incision coaxial cataract surgery using different power modes for hard nuclear cataract.. Journal of cataract and refractive surgery. 2011. DOI: 10.1016/j.jcrs.2011.04.024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.