Endovascular Repair Using a 7-Branch Stent-Graft for a Thoracoabdominal Aortic Aneurysm With Variant Renovisceral Artery Anatomy.

Eleshra Ahmed, Spanos Konstantinos, Panuccio Giuseppe, Gronert Catharina, Rohlffs Fiona, Kölbel Tilo

Клинический случайСтатьяПеревод в очереди

Аннотация

Purpose: To present a case of endovascular repair using a custom-made 7-branch stent-graft for a thoracoabdominal aortic aneurysm (TAAA) in a patient with variations in the renovisceral artery anatomy. Case Report: A 70-year-old asymptomatic man presented with a 60-mm-diameter type IV TAAA. Due to severe coronary artery disease, an endovascular approach was elected. In the preoperative computed tomography angiography (CTA) scans, variations in the renovisceral artery anatomy included the common hepatic and splenic arteries deriving separately from the aorta and bilateral double renal arteries (RAs). A custom-made 7-branch stent-graft was manufactured to preserve all renovisceral arteries. The 7 branches were catheterized and connected with a steerable sheath from a femoral access. All branches were bridged to the target vessel (TV) with a self-expanding covered stent; 4 TVs also had balloon-expandable covered stents implanted. Final angiography and predischarge CTA showed patency of all 7 target vessels and corresponding visceral organs, with no endoleak. The patient was discharged on postoperative day 8 without complications. Six-month follow-up CTA demonstrated exclusion of the TAAA and patency of all 7 target vessels.

Conclusion

Successful treatment of a TAAA in a patient with multiple variant renovisceral arteries was feasible with a custom-made 7-branch stent-graft, achieving a good early outcome.

Для цитирования: Eleshra Ahmed, Spanos Konstantinos, Panuccio Giuseppe, Gronert Catharina, Rohlffs Fiona, Kölbel Tilo. Endovascular Repair Using a 7-Branch Stent-Graft for a Thoracoabdominal Aortic Aneurysm With Variant Renovisceral Artery Anatomy.. Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. 2019. DOI: 10.1177/1526602819892557.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.