MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2017.09.148

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2017

Repair of a quadricuspid truncal valve by tricuspidization and reconstruction of right ventricular outflow tract with the excised truncal cusp.

Wei Ling-Yi, Chen Yih-Sharng, Chiu Ing-Sh, Huang Shu-Chien

Клинический случайСтатьяПеревод в очереди

Аннотация

OBJECTIVE

Quadricuspid truncal valves are susceptible to regurgitation, and tricuspid configuration is considered more durable after repairing the truncal valve. We report a new method by excising the excessive truncal cuspid to reconstruct a new competent aortic valve.

METHODS

Bilateral pulmonary banding failed to stabilize a 4-month-old baby with type I truncus arteriosus and quadricuspid truncal valve with severe regurgitation, so surgery was performed. The aorta was transected, and the pulmonary arteries was separated from the aorta. There was an excessive cusp between the right coronary and left coronary cusp. A transannular incision was carried into the right ventricular outflow tract through the left border of the right coronary cusp. We performed truncal valve repair by translocating the excessive cusp, its annulus, and its wall to the right ventricular outflow tract side and reconstructing the neoaortic valve to tricuspid. Ventricular septal defect was repair through a right ventricular outflow tract approach. The floor of the right ventricular outflow tract was made from the excised cusp, including its wall and the resected posterior aortic wall. Then the anterior wall was reconstructed with bovine pericardial patch with a 19-mm porcine valve.

RESULTS

Postoperative echocardiography confirmed a tricuspid neo-aortic valve with trivial aortic regurgitation, no residual ventricular septal defect, and a patent right ventricular outflow tract.

CONCLUSIONS

We present the surgical technique to repair a quadricuspid truncal valve insufficiency by using the excessive anterior cusp and its pedicled flap for reconstruction of the pulmonary pathway and restoration of the tricuspid truncal valve.

Для цитирования: Wei Ling-Yi, Chen Yih-Sharng, Chiu Ing-Sh, Huang Shu-Chien. Repair of a quadricuspid truncal valve by tricuspidization and reconstruction of right ventricular outflow tract with the excised truncal cusp.. The Journal of thoracic and cardiovascular surgery. 2017. DOI: 10.1016/j.jtcvs.2017.09.148.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.