Feasibility of High-Resolution Oximeter Plus Actigraphy Combined with a Cloud-Based Algorithm for the Detection of Obstructive Sleep Apnea in Children with Craniofacial Anomalies.

Trindade Sergio Henrique Kiemle, Banhara Fábio Luiz, Fidélis da Silva Leide Vilma, Giampá Sara Quaglia de Campos, Sena Lais Mota Furtado, Trindade-Suedam Ivy Kiemle

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To verify the feasibility of high-resolution oximeter plus actigraphy combined with a cloud-based algorithm for the detection of obstructive sleep apnea (OSA) in children with craniofacial anomalies.

MATERIALS AND

METHODS

In the present prospective, cross-sectional study, we evaluated children previously submitted to primary surgical palate repair with a genetically confirmed diagnosis of Treacher Collins syndrome (TCS), non-syndromic Robin sequence (NSRS), or non-syndromic cleft palate (NSCP). The children underwent a clinical evaluation, had their anthropometric measures taken, and were submitted to OSA detection using high-resolution oximeter plus actigraphy combined with a cloud-based algorithm (Biologix Sleep Test, Biologix Sistemas S.A., São Paulo, SP, Brazil).

RESULTS

In total, 64 children (TCS: n = 16; NSRS: n = 29; NSCP: n = 19) were included in the final analysis (mean age: 10 ± 2 years; 64% of female patients). The Biologix Sleep Test showed that 59 patients (92%) presented OSA according to the oxygen desaturation index (ODI): 36 (56%) were diagnosed with mild OSA, 19 (30%), with moderate OSA, and 4 (6%), with severe OSA. The high-resolution oximeter recording showed excellent signal quality in 94.53 ± 5.29% of the exams, with a success rate of exams on the first night of 90%. No significant difference was found in terms of ODI among the subgroups ( p  > 0.05). A significant relationship was observed between increased ODI with greater hypoxic burden and lower estimated sleep efficiency. The multiple linear regression analysis demonstrated a significant association between changes in total ODI with lower estimated sleep efficiency and sleep ODI.

CONCLUSION

High-resolution oximeter plus actigraphy combined with a cloud-based algorithm demonstrated adequate feasibility and applicability for OSA detection in children with craniofacial anomalies.

Для цитирования: Trindade Sergio Henrique Kiemle, Banhara Fábio Luiz, Fidélis da Silva Leide Vilma, Giampá Sara Quaglia de Campos, Sena Lais Mota Furtado, Trindade-Suedam Ivy Kiemle. Feasibility of High-Resolution Oximeter Plus Actigraphy Combined with a Cloud-Based Algorithm for the Detection of Obstructive Sleep Apnea in Children with Craniofacial Anomalies.. Sleep science (Sao Paulo, Brazil). 2025. DOI: 10.1055/s-0045-1802967.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.