MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circep.112.976597

Медицинская библиотека · Circulation. Arrhythmia and electrophysiology · 2012

Atrioventricular node reentrant tachycardia in patients with congenitally corrected transposition of the great arteries and results of radiofrequency catheter ablation.

Liao Zili, Chang Yu, Ma Jian, Fang Pihua, Zhang Kuijun, Ren Xiaoqing, Yang Pingzhen, Yu Bo, Hu Jiqiang, Yang Qian, Ouyang Feifan, Zhang Shu

СтатьяПеревод в очереди

Аннотация

BACKGROUND

We sought to investigate the feasibility of radiofrequency catheter ablation of atrioventricular node reentrant tachycardia and the ideal site for slow pathway (SP) ablation in congenitally corrected transposition of the great arteries.

METHODS AND

RESULTS

Nine patients with congenitally corrected transposition of the great arteries referred for catheter ablation of atrioventricular node reentrant tachycardia were studied. A single His potential was recorded in 8 patients (89%, 6 {S,L,L} and 2 {I,D,D}). The earliest atrial activation during retrograde atrioventricular node conduction occurred at His bundle region (HBE; n=7) or shifting from HBE to coronary sinus ostium (n=1, {S,L,L}). Two anatomically separate His potentials were recorded in 1 patient (11%, {S,L,L}), one at the anteroseptum (HBE-1) and the other at the confluence of the pulmonary and mitral annulus (HBE-2). In 8 cases with a single His potential recorded, SP was abated at the posterior-midseptum, 2 ({S,L,L}) at the right posteroseptum, 1 ({S,L,L}) at the left posteroseptum, and 5 (3 {S,L,L} and 2 {I,D,D}) at the midseptum after failure of energy application at the posteroseptum. Junctional rhythm was observed during radiofrequency catheter ablation in all 8 of the cases. In the remaining patient with 2 anatomically separate His potentials recorded, SP was successfully ablated from the confluence of the pulmonary and mitral annulus, slightly below the HBE-2. Junctional rhythm was also induced during radiofrequency catheter ablation.

CONCLUSIONS

In {S,L,L} or {I,D,D}, radiofrequency catheter ablation of atrioventricular node reentrant tachycardia is feasible. SP input region can mainly be found in the posterior midseptum, especially in patients with single penetrating atrioventricular nodes. SP could usually be successfully ablated in these regions.

Для цитирования: Liao Zili, Chang Yu, Ma Jian, Fang Pihua, Zhang Kuijun, Ren Xiaoqing, Yang Pingzhen, Yu Bo, Hu Jiqiang, Yang Qian, Ouyang Feifan, Zhang Shu. Atrioventricular node reentrant tachycardia in patients with congenitally corrected transposition of the great arteries and results of radiofrequency catheter ablation.. Circulation. Arrhythmia and electrophysiology. 2012. DOI: 10.1161/circep.112.976597.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.