MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00345-023-04485-x

Медицинская библиотека · World journal of urology · 2023

Performance of indocyanine green in sentinel lymph node mapping and lymph node metastasis in penile cancer: systematic review, meta-analysis, and single-center experience.

Zhang Rui, Zhang Yaqin, Dong Sihan, Pang Kai, Yang Xiaofeng, Wei Xunbin

Систематический обзорМетаанализСтатьяПеревод в очереди

Аннотация

PURPOSE: The aim of this study was to investigate the overall sensitivity and specificity of indocyanine green (ICG)-near-infrared (NIR) fluorescence imaging in the detection of sentinel lymph node metastasis (SLNM) in penile cancer.

METHODS

We searched PubMed, Embase, Web of Science, Scopus, and the Cochrane Library databases to identify manuscripts where ICG was intravenously administered prior to or during penile cancer surgery, with no restriction on language or publication status. The results extracted are presented as forest plots.

RESULTS

Seven studies were included in the analysis. The median sensitivity and specificity of ICG-NIR imaging for SLNM detection were 100 and 4%, respectively; the pooled sensitivity was 100.0% (95% confidence interval [CI] 97.0-100.0) and specificity was 2.0% (95% CI 1.0-3.0). There was no significant difference in the diagnostic results between different injection sites and doses in each experimental group.

CONCLUSION

To our knowledge, this meta-analysis is the first to summarize the diagnostic performance of ICG-NIR imaging for SLNM detection in penile cancer. ICG is sensitive in the imaging of SLN tissue, which can consequently improve the accuracy of lymph node detection. However, the specificity is very low.

Для цитирования: Zhang Rui, Zhang Yaqin, Dong Sihan, Pang Kai, Yang Xiaofeng, Wei Xunbin. Performance of indocyanine green in sentinel lymph node mapping and lymph node metastasis in penile cancer: systematic review, meta-analysis, and single-center experience.. World journal of urology. 2023. DOI: 10.1007/s00345-023-04485-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.