MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0003-4975(98)00185-4

Медицинская библиотека · The Annals of thoracic surgery · 1998

Behavior of mitral allografts in the tricuspid position in the growing sheep model.

Bernal J M, Rabasa J M, Cagigas J C, Val F, Revuelta J M

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

On the basis of a previous experience in a chronic sheep model in which partial mitral allografts remained viable and properly functioning 12 months after operation, we assessed the results obtained by replacing the tricuspid valve with fresh antibiotic-preserved mitral allografts.

METHODS

Twenty 3-month-old sheep with a mean weight of 23.7 +/- 2.3 kg underwent cardiopulmonary bypass and had a fresh antibiotic-preserved mitral allograft implanted in the tricuspid position with the heart beating under normothermic conditions. The tricuspid valve apparatus was not excised. After a mean follow-up of 13.2 months, the allograft was evaluated by gross inspection and light and electron microscopy.

RESULTS

Nine sheep died of technical causes within the first week after operation and 2 at 4 and 6 months of infective endocarditis of the allograft. The hemodynamic study before heart explantation revealed residual tricuspid incompetence in 3 of the 9 survivors. Macroscopic examination showed flexible valves with no signs of structural deterioration, calcification, or thrombosis. Under light and scanning electron microscopic examination, allografts were almost completely denuded of endothelial cells and showed loosely arranged connective tissue with scarce signs of inflammatory reaction. Despite these findings, allografts were free from major structural damage.

CONCLUSIONS

The mitral homograft could be an alternative to replacement of the tricuspid valve with a bioprosthesis or a mechanical prosthesis.

Для цитирования: Bernal J M, Rabasa J M, Cagigas J C, Val F, Revuelta J M. Behavior of mitral allografts in the tricuspid position in the growing sheep model.. The Annals of thoracic surgery. 1998. DOI: 10.1016/s0003-4975(98)00185-4.

Предметные рубрики MeSH