DOI 10.1016/j.ajem.2019.02.014
Aspartate-aminotransferase to platelet ratio index score for predicting HELLP syndrome.
Аннотация
INTRODUCTION
HELLP (hemolysis, elevated liver enzyme levels, low platelet counts)-syndrome is a rare but dramatic pregnancy-related illness. The difficult part of this syndrome is the lack of standardised diagnostic criterias and tests to be used to predict it. The aim of this study is determining the role of APRI score in the diagnosis of HELLP syndrome.
MATERIAL AND
METHODS
In this cross sectional, retrospective study, patients with HELLP syndrome as case group and age-matched healthy pregnants at the similar pregnancy trimester as control group were included between January 12,017 and May 31, 2018. Data including sex, age, laboratory values, prognosis were recorded from the computerized system of the hospital. The p-value <0.05 was considered statistically significant.
RESULTS
40 patients with HELLP syndrome and 124 age-matched healthy pregnants included in the study. There was a statistically significant difference between control group and HELLP patients in terms of the mean urinary protein, platelet count, ALT, AST, creatinin, D dimer levels and also the mean APRI score. In the multivariate regression analysis, APRI score was found a better predictor than AST and both were in a good significant in predicting HELLP. On the ROC curve in order to distinguish the patients with HELLP from the control group for AST and APRI score, the sensitivity was found to be 71.7% and 82.6%, specificity to be 91.2% and 87.6% respectively. Maternal mortality rate of HELLP syndrome was 10%.
CONCLUSION
We concluded that the APRI score was robustly predicted HELLP syndrome than AST alone in this study. Further studies are needed to support our data with prospective, multicentre, larger patient groups.