MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jse.2013.08.004

Медицинская библиотека · Journal of shoulder and elbow surgery · 2013

Medial grasping sutures significantly improve load to failure of the rotator cuff suture bridge repair.

Awwad George E, Eng Kevin, Bain Gregory I, McGuire Duncan, Jones Claire F

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The suture bridge (SB) transosseous-equivalent rotator cuff repair reduces re-tear rates compared with single-row or other double-row constructs. However, failure rates continue to be high, especially in large and massive tears. The aim of this study was to assess the biomechanical performance of a new SB repair with use of a medial grasping suture compared with the traditional SB repair.

METHODS

Seven matched pairs of sheep infraspinatus tendons were randomly assigned to either SB or suture bridge with grasping suture (SBGS) repair. Each construct was subjected to cyclic loading and then loaded until failure under displacement control in a materials testing machine. Footprint displacement, ultimate load to failure, and mode of failure were assessed.

RESULTS

The rotator cuff footprint displacement was less during tensile loading with the addition of the medial grasping suture. The ultimate load to failure was significantly greater for the SBGS repair group than for the SB repair group (334.0 N vs 79.8 N). The mode of failure was the tendon pulling off the footprint in all cases (type 1 tear). There were no failures in which the tendon tore at the medial row of anchors, leaving part of the tendon still on the footprint (type 2 tear).

CONCLUSION

The addition of a medial grasping suture significantly improved the ultimate load to failure and reduced the footprint displacement of the SB rotator cuff repair in a biomechanical model.

Для цитирования: Awwad George E, Eng Kevin, Bain Gregory I, McGuire Duncan, Jones Claire F. Medial grasping sutures significantly improve load to failure of the rotator cuff suture bridge repair.. Journal of shoulder and elbow surgery. 2013. DOI: 10.1016/j.jse.2013.08.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.