DOI 10.1097/ico.0000000000002433
The Search for Antifungal Prophylaxis After Artificial Corneal Surgery-An In Vitro Study.
Аннотация
PURPOSE: To evaluate the antifungal properties of topical antibiotics (already being used successfully to prevent bacterial endophthalmitis) and some promising antiseptics for antifungal prophylaxis in the setting of artificial corneal implantation.
METHODS
Several commonly used antibiotics for antimicrobial prophylaxis after artificial corneal implantation, in addition to antiseptics [benzalkonium chloride (BAK), povidone-iodine (PI), and some ionic liquids (ILs)], were tested in vitro against Candida albicans, Fusarium solani, and Aspergillus fumigatus. The time-kill activity was determined. Toxicity was assayed in vitro on human corneal epithelial cultures using trypan blue. Adhesion and tissue invasion experiments were also carried out on porcine corneas and commonly used contact lenses, with or without gamma irradiation, and by analysis with fluorescence microscopy.
RESULTS
Polymyxin B (PMB)/trimethoprim/BAK (Polytrim), PMB alone, gatifloxacin with BAK (Zymaxid), and same-concentration BAK alone exhibited antifungal activity in vitro. Moxifloxacin (MOX) or gatifloxacin without BAK-as well as trimethoprim, vancomycin, and chloramphenicol-had no effect. 1% PI and ILs had the highest efficacy/toxicity ratios (>1), and Polytrim was species dependent. Subfungicidal concentrations of Polytrim reduced adhesion of C. albicans to Kontur contact lenses. Gamma-irradiated corneas showed enhanced resistance to fungal invasion.
CONCLUSIONS
Of antibiotic preparations already in use for bacterial prophylaxis after KPro surgery, Polytrim is a commonly used antibiotic with antifungal effects mediated by both PMB and BAK and may be sufficient for prophylaxis. PI as a 1% solution seems to be promising as a long-term antifungal agent. Choline-undecanoate IL is effective and virtually nontoxic and warrants further development.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.