MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12959-021-00279-6

Медицинская библиотека · Thrombosis journal · 2021

Cardiac implantable electronic device surgery with interruption of warfarin forgoing post-operative bridging therapy in patients with moderate or high thromboembolic risks.

Ng Andrew Kei-Yan, Ng Pauline Yeung, Tam Eva Wai-Ying, Siu Chung-Wah, Fan Katherine

СтатьяПеревод в очереди

Аннотация

BACKGROUND

For patients taking warfarin and undergoing pacemaker or implantable cardioverter-defibrillator surgery, clinical evidence and guidelines support continuation of warfarin therapy, as opposed to interruption of warfarin therapy with heparin bridging. Interruption of warfarin without post-operative bridging therapy may be a feasible alternative but data is sparse.

METHODS

This is a single-arm observational study including adults who had interruption of warfarin therapy without post-operative bridging therapy for cardiac implantable electronic device (CIED) surgery performed between 2010 and 2019 in a tertiary referral hospital. The primary outcome was a composite of all-cause mortality, arterial or venous thromboembolic events. The secondary outcomes were clinically significant device-pocket hematoma and other procedural complications.

RESULTS

Of the 411 patients analysed including 257 patients (62.5%) who had mechanical heart valves, the primary outcome developed in 5 (1.2%) patients within 30 days after surgery, including death in 3 (0.7%) patients, transient ischemic attack in 1 (0.2%) patient and non-CNS embolism in 1 (0.2%) patient. Clinically significant hematomas occurred in 24 (5.8%) patients, including 15 (3.7%) requiring additional interruption of anti-coagulation and 6 (1.5%) requiring clot evacuation. Other procedural complications and bleeding events were rare (< 1%).

CONCLUSIONS

Warfarin interruption without post-operative bridging therapy for CIED surgery was associated with low thromboembolic risks and acceptable bleeding risk. Randomized controlled trials are required to formulate an optimal approach to anti-coagulation management.

Для цитирования: Ng Andrew Kei-Yan, Ng Pauline Yeung, Tam Eva Wai-Ying, Siu Chung-Wah, Fan Katherine. Cardiac implantable electronic device surgery with interruption of warfarin forgoing post-operative bridging therapy in patients with moderate or high thromboembolic risks.. Thrombosis journal. 2021. DOI: 10.1186/s12959-021-00279-6.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.