MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1164/rccm.201103-0577oc

Медицинская библиотека · American journal of respiratory and critical care medicine · 2011

Loop gain as a means to predict a positive airway pressure suppression of Cheyne-Stokes respiration in patients with heart failure.

Sands Scott A, Edwards Bradley A, Kee Kirk, Turton Anthony, Skuza Elizabeth M, Roebuck Teanau, O'Driscoll Denise M, Hamilton Garun S, Naughton Matthew T, Berger Philip J

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод в очереди

Аннотация

RATIONALE: Patients with heart failure (HF) and Cheyne-Stokes respiration or periodic breathing (PB) often demonstrate improved cardiac function when treatment with continuous positive airway pressure (CPAP) resolves PB. Unfortunately, CPAP is successful in only 50% of patients, and no known factor predicts responders to treatment. Because PB manifests from a hypersensitive ventilatory feedback loop (elevated loop gain [LG]), we hypothesized that PB persists on CPAP when LG far exceeds the critical threshold for stable ventilation (LG = 1).

OBJECTIVES

To derive, validate, and test the clinical utility of a mathematically precise method that quantifies LG from the cyclic pattern of PB, where LG = 2π/(2πDR - sin2πDR) and DR (i.e., duty ratio) = (ventilatory duration)/(cycle duration) of PB.

METHODS

After validation in a mathematical model of HF, we tested whether our estimate of LG changes with CPAP (n = 6) and inspired oxygen (n = 5) as predicted by theory in an animal model of PB. As a first test in patients with HF (n = 14), we examined whether LG predicts the first-night CPAP suppression of PB.

MEASUREMENTS AND MAIN

RESULTS

In lambs, as predicted by theory, LG fell as lung volume increased with CPAP (slope = 0.9 ± 0.1; R(2) = 0.82; P < 0.001) and as inspired-arterial PO(2) difference declined (slope = 1.05 ± 0.12; R(2) = 0.75; P < 0.001). In patients with HF, LG was markedly greater in 8 CPAP nonresponders versus 6 responders (1.29 ± 0.04 versus 1.10 ± 0.01; P < 0.001); LG predicted CPAP suppression of PB in 13/14 patients.

CONCLUSIONS

Our novel LG estimate enables quantification of the severity of ventilatory instability underlying PB, making possible a priori selection of patients whose PB is immediately treatable with CPAP therapy.

Для цитирования: Sands Scott A, Edwards Bradley A, Kee Kirk, Turton Anthony, Skuza Elizabeth M, Roebuck Teanau, O'Driscoll Denise M, Hamilton Garun S, Naughton Matthew T, Berger Philip J. Loop gain as a means to predict a positive airway pressure suppression of Cheyne-Stokes respiration in patients with heart failure.. American journal of respiratory and critical care medicine. 2011. DOI: 10.1164/rccm.201103-0577oc.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.