Accuracy of plain radiography in detecting fractures in older individuals after low-energy falls: current evidence.
Аннотация
BACKGROUND
Older individuals sustaining low-energy falls (LEF) and presenting to the emergency department (ED) demand straightforward diagnostic measures for injury detection. Plain radiography (XR) series for diagnosis of fall-related injuries are standard of care, but frequently subsequent CT examination is required for diagnostic assurance. A systematic database search of diagnostic accuracy of XR for detection of fractures in older LEF patients was performed.
METHODS
We searched PubMed, Embase, Cochrane Library, WHO International Clinical Trial Platform, and Clinical trials.gov databases from inception to January 2020 for studies including older patients (≥65 years) with LEF and obtaining CT examination and XR of the skeleton in an ED setting.
RESULTS
From 8944 references screened, 11 studies met the criteria for inclusion. Performance of XR for detection of fractures of the pelvic ring and hip was analyzed in nine studies, two studies investigated XR performance to detect rib fractures, and two studies compared diagnostic accuracy of thoracolumbar spine XR. Sensitivity estimates ranged from 10% to 58% and specificity estimates from 55% to 100%. Clinical and statistical heterogeneity was significant among included studies, with an overall considerable risk of bias.
DISCUSSION: High-quality evidence on accurate imaging strategies in older patients with LEF is lacking to date. XR is missing a reasonable amount of fractures of the pelvic ring, rib cage, and thoracic and lumbar spine. However, the utility of first-line CT imaging and the benefit of diagnosing every fracture is unknown, demanding high-quality prospective trials considering patient-oriented outcome as well.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.