MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/1558944719840737

Медицинская библиотека · Hand (New York, N.Y.) · 2019

The Pronator Quadratus Muscle After Volar Plating: Ultrasound Evaluation of Anatomical Changes Correlated to Patient-Reported Clinical Outcome.

Sonntag Jesper, Hern Jesper, Woythal Linn, Branner Ulrik, Lange Kai H W, Brorson Stig

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Background

Repair of the pronator quadratus (PQ) muscle with sutures has been reported durable after volar plating of distal radius fractures (DRF). It is unclear how the muscle reacts if not repaired and if a retracted muscle correlates to worse functional outcome or complications. In this study, we use ultrasound to investigate the anatomy of the PQ muscle after volar plating with PQ repair or nonrepair and correlate the ultrasound findings with patient-reported outcome.

Methods

Participants were recruited from a clinical trial where they were randomly allocated to repair or nonrepair of the PQ muscle after volar plating of DRF. The participants and radiologist were blinded to group allocation. Ultrasound imaging of both fractured and contralateral wrists was performed 3 months after surgery. Ultrasound measurements included the difference in length of PQ muscle between the injured and uninjured side, retraction of PQ muscle, and tendon complications. The length and number of retractions were correlated to complications and Patient-Rated Wrist Evaluation (PRWE).

Results

The mean difference of the difference in length measurements was 4.4 mm in the nonrepair group and 2.7 mm in the repair group with a mean difference between groups of 1.7 mm. This was statically significant; however, there were no clinical or statistical differences in complication rate or PRWE between the two groups.

Conclusion

The PQ length was significantly shorter and the number of retractions significantly larger without repair of the PQ muscle; however, neither length nor retraction correlated significantly with complication rate or PRWE.

Для цитирования: Sonntag Jesper, Hern Jesper, Woythal Linn, Branner Ulrik, Lange Kai H W, Brorson Stig. The Pronator Quadratus Muscle After Volar Plating: Ultrasound Evaluation of Anatomical Changes Correlated to Patient-Reported Clinical Outcome.. Hand (New York, N.Y.). 2019. DOI: 10.1177/1558944719840737.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.