MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1089/dia.2023.0267

Медицинская библиотека · Diabetes technology & therapeutics · 2023

MiniMedTM 780G Advanced Hybrid Closed-Loop System Study in Pregnant Women with Type 1 Diabetes.

Guibert Clara, Amoura Lamia, Rakotoarisoa Luc, Plat Francoise, Sonnet Emmanuel, Lablanche Sandrine, Tréglia Clémence, Sarde Elisa, Leca Viviane, Rimareix Frédérique, Melki Vincent, Baucher Franciane, Betari Bouchra, Meyer Laurent, Kessler Laurence

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод в очереди

Аннотация

Background

Evaluate the impact of the MiniMed™ 780G advanced hybrid closed-loop (AHCL) system on the glucose profile of pregnant women with type 1 diabetes (T1D) and maternal-neonatal complications.

Methods

From April 2021 to September 2022, pregnant women with T1D treated with the AHCL system were included in an observational multicenter retrospective study. Continuous glucose monitoring parameters were analyzed monthly during pregnancy as well as maternal-neonatal complications.

Results

Thirteen pregnant women, including a twin pregnancy (age: 33 ± 3 years, hemoglobin A1c [HbA1c]: 7.3% ± 0.7%, insulin doses: 0.72 ± 0.21 U/kg/day) were analyzed. At delivery, gestational age was 37 ± 2 weeks. During first 2 weeks of pregnancy, time in range (TIR, 63-140 mg/dL) was 46% (34-55) and increased to 54% (51-59) (P < 0.01), 64% (48-68) (P < 0.01), and 66% (60-70) (P < 0.001) during the first, second, and third trimester, respectively. During the night, TIR (63-140 mg/dL) was >70% throughout pregnancy. Time below the range <63 mg/dL increased from 0.5% (0-2) to 1.3% (0.7-2.2), 2% (1.2-3.5) (P < 0.05), and 1.3% (1.31-3) (P < 0.05) during the first, second, and third trimester, respectively. At delivery, insulin doses increased to 0.89 ± 0.35 IU/kg/day (P < 0.01), and HbA1c decreased to 6.4% ± 0.6% (P = 0.005). The reported carbohydrate amount increased from 167 ± 363 g/d during early pregnancy to 243 ± 106 g/d (P < 0.01) at delivery. The birthweight was 3134 ± 711 g, with 5/14 macrosomia and 2/14 neonatal hypoglycemia. Moreover, 5/13 patients had a preeclampsia and 9/13 a cesarean section, including three cases of scarred uterus. The Clinical Trial Registration number is: CE-2022-55.

Conclusion

The AHCL system provided good glucose control during pregnancy and recommendation targets were reached during the nocturnal period only. The maternal and neonatal complications remained high.

Для цитирования: Guibert Clara, Amoura Lamia, Rakotoarisoa Luc, Plat Francoise, Sonnet Emmanuel, Lablanche Sandrine, Tréglia Clémence, Sarde Elisa, Leca Viviane, Rimareix Frédérique, Melki Vincent, Baucher Franciane, Betari Bouchra, Meyer Laurent, Kessler Laurence. MiniMedTM 780G Advanced Hybrid Closed-Loop System Study in Pregnant Women with Type 1 Diabetes.. Diabetes technology & therapeutics. 2023. DOI: 10.1089/dia.2023.0267.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.