MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acssensors.5c01445

Медицинская библиотека · ACS sensors · 2025

Harnessing the Power of a H2O2-Activated Theranostic Probe against Doxorubicin-Induced Cardiotoxicity.

Cao Zhixing, Li Jia, Yang Wenya, Cui Jianwei, Xiang Peini, Li Yuzhi, Deng Yun, Xie Dachun, Peng Cheng, Lu Jun, Hou Ji-Ting, Fang Yuyu

СтатьяПеревод в очереди

Аннотация

Doxorubicin (Dox) is a highly effective antitumor drug with established therapeutic benefits across various tumor types, whose non-negligible and potent side effect is the Dox-induced cardiotoxicity (DIC). Early diagnosis of DIC is difficult, and available therapeutic regimens are quite limited. Inspired by the unique structure and efficient anti-DIC bioactivity of the natural compound tanshinone IIA (Tan IIA), we rationally developed its fluorescently emissive analogue TOP with preserved anti-DIC efficacy. Especially, TOP was fabricated into a hydrogen peroxide (H2O2)-responsive prodrug TOP-B, which could be activated by the oxidation stress during DIC, thereby facilitating the simultaneous fluorescence monitoring and treatment of DIC. Specifically, monitoring the fluctuation of H2O2 with the probe TOP-B can directly reflect the progression of DIC in the cardiomyocyte, zebrafish, and mouse models. TOP-B can also promote the expression of antioxidant proteins, which contribute to the alleviation of DIC. Needless to say, probe TOP-B not only serves as a promising therapeutic drug and fluorescence-guided imaging agent for DIC, but more importantly provides inspiration to construct other rationally designed theranostic probes derived from the natural product skeletons for specific diseases.

Другие публикации по теме

DoxorubicinHydrogen PeroxideCardiotoxicityZebrafish
Для цитирования: Cao Zhixing, Li Jia, Yang Wenya, Cui Jianwei, Xiang Peini, Li Yuzhi, Deng Yun, Xie Dachun, Peng Cheng, Lu Jun, Hou Ji-Ting, Fang Yuyu. Harnessing the Power of a H2O2-Activated Theranostic Probe against Doxorubicin-Induced Cardiotoxicity.. ACS sensors. 2025. DOI: 10.1021/acssensors.5c01445.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.