The Journal of allergy and clinical immunology · 2021
Defining baseline variability of serum tryptase levels improves accuracy in identifying anaphylaxis.
СтатьяПоддержка NIH: внешняя программаResearch Support, N.I.H., IntramuralНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Mateja Allyson, Wang Qinlu, Chovanec Jack, Kim Jiwon, Wilson Kenneth J, Schwartz Lawrence B, Glover Sarah C, Carter Melody C, Metcalfe Dean D, Brittain Erica, Lyons Jonathan J
Аннотация
BACKGROUND: Acute increases of ≥20% + 2 ng/mL (20 + 2 rule) over basal serum tryptase (BST) is the recommended threshold supporting a clinical diagnosis of anaphylaxis. Prospective studies have demonstrated high sensitivity for this algorithm after parenteral exposure, but specificity has not been evaluated.
OBJECTIVE: We sought to define a serum tryptase change that distinguishes baseline variability from anaphylaxis on the basis of intraindividual variation in BST.
METHODS: Ninety-three total subjects with atopy (n = 62) or hereditary α-tryptasemia (HαT) (n = 31) and ≥2 BST measurements were identified. Sequential BST variability measurements were modeled and threshold ratios that optimized sensitivity and/or specificity determined. Models were tested in 22 individuals with physician-diagnosed anaphylaxis and validated in independent cohorts of individuals with HαT (n = 33), indolent systemic mastocytosis (ISM) (n = 52), and ISM + HαT (n = 12). Mature tryptase levels were measured in HαT (n = 19) and ISM (n = 20). An online application was developed for clinical use.
RESULTS: As a result of BST variability, 9.7% (9/93) of primary cohort patients, and 18% (6/33) of HαT, 30% (16/53) of ISM, and 25% (3/12) of ISM + HαT patients from validation cohorts met the 20 + 2 rule despite absent immediate hypersensitivity symptoms; mature tryptase was noncontributory among individuals with HαT or ISM at baseline. A ratio of acute tryptase/BST exceeding 1.685 provided the optimized diagnostic rule for jointly maximizing sensitivity and specificity. Statistically significant improvement in specificity relative to the 20 + 2 rule was observed among individuals with elevated BST caused by HαT and ISM.
CONCLUSIONS: Using an acute tryptase/BST ratio of 1.685 improves specificity of measured changes among individuals with HαT and ISM while maintaining high sensitivity for confirmation of anaphylaxis.
OBJECTIVE: We sought to define a serum tryptase change that distinguishes baseline variability from anaphylaxis on the basis of intraindividual variation in BST.
METHODS: Ninety-three total subjects with atopy (n = 62) or hereditary α-tryptasemia (HαT) (n = 31) and ≥2 BST measurements were identified. Sequential BST variability measurements were modeled and threshold ratios that optimized sensitivity and/or specificity determined. Models were tested in 22 individuals with physician-diagnosed anaphylaxis and validated in independent cohorts of individuals with HαT (n = 33), indolent systemic mastocytosis (ISM) (n = 52), and ISM + HαT (n = 12). Mature tryptase levels were measured in HαT (n = 19) and ISM (n = 20). An online application was developed for clinical use.
RESULTS: As a result of BST variability, 9.7% (9/93) of primary cohort patients, and 18% (6/33) of HαT, 30% (16/53) of ISM, and 25% (3/12) of ISM + HαT patients from validation cohorts met the 20 + 2 rule despite absent immediate hypersensitivity symptoms; mature tryptase was noncontributory among individuals with HαT or ISM at baseline. A ratio of acute tryptase/BST exceeding 1.685 provided the optimized diagnostic rule for jointly maximizing sensitivity and specificity. Statistically significant improvement in specificity relative to the 20 + 2 rule was observed among individuals with elevated BST caused by HαT and ISM.
CONCLUSIONS: Using an acute tryptase/BST ratio of 1.685 improves specificity of measured changes among individuals with HαT and ISM while maintaining high sensitivity for confirmation of anaphylaxis.