MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00405-013-2521-1

Медицинская библиотека · European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2013

Hazard of CO₂ laser-induced airway fire in laryngeal surgery: experimental data of contributing factors.

Stuermer Konrad Johannes, Ayachi Stefan, Gostian Antoniu-O, Beutner Dirk, Hüttenbrink Karl-Bernd

СтатьяПеревод в очереди

Аннотация

In carbon dioxide (CO2) laser surgery of the larynx, the potentially dangerous combination of laser-induced heat in an oxygen-enriched atmosphere typically occurs when jet ventilation is used or due to an insufficiently blocked endotracheal tube. Until now, no limitations for safe oxygen concentrations or laser intervals have been established. The aim of this study was to investigate and quantify the factors that may contribute to an airway fire in laryngeal laser surgery. Fat, muscle and cartilage were irradiated with a CO2 laser at 2, 4, 6 and 8 W in five different oxygen concentrations with and without smoke exhaustion. The time to ignition was recorded for each different experimental setup. Fat burnt fastest, followed by cartilage and muscle. The elevation of laser energy or oxygen concentration reduced the time to inflammation of any tissue. The elevation of oxygen by 10 % increases the risk of inflammation more than the elevation of laser power by 2 W. Under smoke exhaustion, inflammation and burning occurred delayed or were even inhibited at lower oxygen concentrations. Lasing in more than 50 % oxygen is comparatively dangerous and can cause airway fire in less than 5 s, especially when laser energies of more than 5 W are applied. In equal or lower than 50 % oxygen, an irradiation interval of 5 s can be considered a comparatively safe time limit to prevent inflammation in laryngeal laser surgery. Smoke exhaustion should always be applied.

Для цитирования: Stuermer Konrad Johannes, Ayachi Stefan, Gostian Antoniu-O, Beutner Dirk, Hüttenbrink Karl-Bernd. Hazard of CO₂ laser-induced airway fire in laryngeal surgery: experimental data of contributing factors.. European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery. 2013. DOI: 10.1007/s00405-013-2521-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.