DOI 10.1007/s10840-020-00775-1
Long-term outcomes of ablation for ventricular arrhythmias in mitral valve prolapse.
Аннотация
PURPOSE: Prior studies reporting efficacy of radiofrequency catheter ablation for complex ventricular ectopy in mitral valve prolapse (MVP) are limited by selective inclusion of bileaflet MVP, papillary muscle only ablation, or short-term follow-up. We sought to evaluate the long-term incidence of hemodynamically significant ventricular tachycardia (VT) or fibrillation (VF) in patients with MVP after initial ablation.
METHODS
We studied consecutive patients with MVP undergoing ablation for complex ventricular ectopy between 2013 and 2017 at our institution. Of 580 patients with MVP, we included 15 (2.6%, 10 women; mean age 50 ± 14 years, 53% bileaflet) with complex ventricular ectopy treated with initial ablation.
RESULTS
Over a median follow-up of 3406 (1875-6551) days or 9 years, 5 of 15 (33%) patients developed hemodynamically significant VT/VF after their initial ablation and underwent placement of an implantable cardioverter defibrillator (ICD). Three of 5 also underwent repeat ablations. Sustained VT was inducible prior to index ablation in all 5 who developed VT/VF, compared to none of the 10 patients who did not develop VT/VF after index ablation (p = 0.002). Complex ventricular ectopy at index ablation was multifocal in all 5 patients who underwent repeat intervention versus 4 of 10 patients (40%) who did not (p = 0.04). All 3 patients with subsequent VT/VF who underwent repeat ablation had a new clinically dominant focus of ventricular arrhythmia and 3 of the patients with ICD had appropriate VT/VF therapies.
CONCLUSIONS
In the long term, a subset of MVP patients treated with ablation for ventricular arrhythmias, all with multifocal ectopy on initial EP study, develop hemodynamically significant VT/VF. Our findings suggest the progressive nature of ventricular arrhythmias in patients with MVP and multifocal ectopy.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.