Reasons for using swelling ratio in sonographic diagnosis of carpal tunnel syndrome and a reliable method for its calculation.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Ulaşli Alper Murat, Duymuş Mahmut, Nacir Bariş, Rana Erdem Hatice, Koşar Uğur
Аннотация
INTRODUCTION: The aim of this study was to investigate factors affecting median nerve cross-sectional area (CSA) and determine a dependable swelling ratio (SR) calculation method.
METHODS: Using ultrasonography, median nerve CSAs were measured at the tunnel inlet, midtunnel, and outlet, and at 4 cm and 12 cm proximal to the wrist. We used CSAmax as the largest of the tunnel measurements and calculated swelling ratios (SRs) by using the CSAmax. Sonographic measurements were correlated with electrophysiologic findings. We evaluated the effects of gender, weight, and height on median nerve thickness.
RESULTS: We studied 95 wrists of 55 CTS patients and 48 wrists of 27 volunteers. Gender, weight, and height had effects on certain median nerve CSA measurements. CSAmax, SRmax4, and SRmax12 had superior correlations with electrophysiologic findings. The correlation between 4-cm and 12-cm median nerve CSAs was statistically significant (r = 0.879 and P < 0,001).
CONCLUSION: We have developed a reliable SR method considering factors affecting median nerve CSA.
METHODS: Using ultrasonography, median nerve CSAs were measured at the tunnel inlet, midtunnel, and outlet, and at 4 cm and 12 cm proximal to the wrist. We used CSAmax as the largest of the tunnel measurements and calculated swelling ratios (SRs) by using the CSAmax. Sonographic measurements were correlated with electrophysiologic findings. We evaluated the effects of gender, weight, and height on median nerve thickness.
RESULTS: We studied 95 wrists of 55 CTS patients and 48 wrists of 27 volunteers. Gender, weight, and height had effects on certain median nerve CSA measurements. CSAmax, SRmax4, and SRmax12 had superior correlations with electrophysiologic findings. The correlation between 4-cm and 12-cm median nerve CSAs was statistically significant (r = 0.879 and P < 0,001).
CONCLUSION: We have developed a reliable SR method considering factors affecting median nerve CSA.
Предметные рубрики MeSH
Action PotentialsAdultAgedArea Under CurveBody HeightBody Mass IndexBody WeightCarpal Tunnel SyndromeCross-Sectional StudiesDemographyEdemaElectrodiagnosisFemaleHumansMaleMedian NerveMiddle AgedProspective StudiesROC CurveReference StandardsReproducibility of ResultsSex CharacteristicsUltrasonography