MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.mvr.2021.104167

Медицинская библиотека · Microvascular research · 2021

Assessment of the conjunctival microcirculation in adult patients with cyanotic congenital heart disease compared to healthy controls.

Brennan Paul F, Jing Min, McNeil Andrew J, Awuah Agnes, Mailey Jonathan, Kelly Bronagh, Finlay Dewar D, Blighe Kevin, McLaughlin James A D, Nesbit M Andrew, Trucco Emanuele, Lockhart Christopher J, Moore Tara C B, Spence Mark S

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: Congenital heart disease (CHD) is the most common live birth defect and a proportion of these patients have chronic hypoxia. Chronic hypoxia leads to secondary erythrocytosis resulting in microvascular dysfunction and increased thrombosis risk. The conjunctival microcirculation is easily accessible for imaging and quantitative assessment. It has not previously been studied in adult CHD patients with cyanosis (CCHD).

METHODS

We assessed the conjunctival microcirculation and compared CCHD patients and matched healthy controls to determine if there were differences in measured microcirculatory parameters. We acquired images using an iPhone 6s and slit-lamp biomicroscope. Parameters measured included diameter, axial velocity, wall shear rate and blood volume flow. The axial velocity was estimated by applying the 1D + T continuous wavelet transform (CWT). Results are for all vessels as they were not sub-classified into arterioles or venules.

RESULTS

11 CCHD patients and 14 healthy controls were recruited to the study. CCHD patients were markedly more hypoxic compared to the healthy controls (84% vs 98%, p = 0.001). A total of 736 vessels (292 vs 444) were suitable for analysis. Mean microvessel diameter (D) did not significantly differ between the CCHD patients and controls (20.4 ± 2.7 μm vs 20.2 ± 2.6 μm, p = 0.86). Axial velocity (Va) was lower in the CCHD patients (0.47 ± 0.06 mm/s vs 0.53 ± 0.05 mm/s, p = 0.03). Blood volume flow (Q) was lower for CCHD patients (121 ± 30pl/s vs 145 ± 50pl/s, p = 0.65) with the greatest differences observed in vessels >22 μm diameter (216 ± 121pl/s vs 258 ± 154pl/s, p = 0.001). Wall shear rate (WSR) was significantly lower for the CCHD group (153 ± 27 s-1 vs 174 ± 22 s-1, p = 0.04).

CONCLUSIONS

This iPhone and slit-lamp combination assessment of conjunctival vessels found lower axial velocity, wall shear rate and in the largest vessel group, lower blood volume flow in chronically hypoxic patients with congenital heart disease. With further study this assessment method may have utility in the evaluation of patients with chronic hypoxia.

Для цитирования: Brennan Paul F, Jing Min, McNeil Andrew J, Awuah Agnes, Mailey Jonathan, Kelly Bronagh, Finlay Dewar D, Blighe Kevin, McLaughlin James A D, Nesbit M Andrew, Trucco Emanuele, Lockhart Christopher J, Moore Tara C B, Spence Mark S. Assessment of the conjunctival microcirculation in adult patients with cyanotic congenital heart disease compared to healthy controls.. Microvascular research. 2021. DOI: 10.1016/j.mvr.2021.104167.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.