MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/j.jcrs.0000000000001874

Медицинская библиотека · Journal of cataract and refractive surgery · 2026

Nomogram for predicting significant rotation after plate-haptic toric intraocular lens implantation in a Chinese population.

Lin Xuanqiao, Hua Zhixiang, Shen Wenqian, Zhuo Baoxian, Shen Jiying, Zhang Limei, Bai Lifang, Cai Lei, Yang Jin

СтатьяНаблюдательное исследованиеМногоцентровое исследованиеПеревод в очереди

Аннотация

PURPOSE: To identify independent risk factors associated with significant postoperative rotation (≥10 degrees) of plate-haptic toric intraocular lenses (IOLs) and to develop and externally validate a predictive nomogram.

SETTING

2 independent eye centers in China.

DESIGN

Prospective observational study with a training cohort and an external validation cohort.

METHODS

805 eyes from 805 cataract patients with regular corneal astigmatism (≥0.75 diopter) who underwent phacoemulsification and plate-haptic toric IOL implantation between August 2021 and December 2024 were included. Patients from 1 center formed the training cohort, while patients from the second center served as the external validation cohort. Least absolute shrinkage and selection operator regression followed by multivariate logistic regression was used to identify predictors of significant toric IOL rotation (≥10 degrees at 2 weeks postoperatively). A predictive nomogram was developed and validated through receiver operating characteristic analysis, calibration curve, and decision curve analysis (DCA).

RESULTS

Age (odds ratio [OR] = 1.04, P = .002), anterior chamber depth (ACD) (OR = 7.71, P < .001), lens thickness (LT) (OR = 5.13, P < .001), and white-to-white (WTW) (OR = 2.36, P = .002) were identified as independent predictors. The nomogram demonstrated good discriminative performance with an area under the curve of 0.809 in the training cohort and 0.848 in the validation cohort. Calibration and DCA analyses confirmed the accuracy and clinical utility of the model.

CONCLUSIONS

A validated nomogram based on age, ACD, LT, and WTW provides a useful tool for individualized preoperative risk assessment of significant toric IOL rotation, aiding surgical decision-making.

Для цитирования: Lin Xuanqiao, Hua Zhixiang, Shen Wenqian, Zhuo Baoxian, Shen Jiying, Zhang Limei, Bai Lifang, Cai Lei, Yang Jin. Nomogram for predicting significant rotation after plate-haptic toric intraocular lens implantation in a Chinese population.. Journal of cataract and refractive surgery. 2026. DOI: 10.1097/j.jcrs.0000000000001874.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.