DOI 10.1371/journal.pone.0047295

Медицинская библиотека · PloS one · 2012

T2-signal of ulnar nerve branches at the wrist in guyon's canal syndrome.

Kollmer Jennifer, Bäumer Philipp, Milford David, Dombert Thomas, Staub Frank, Bendszus Martin, Pham Mirko

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To evaluate T2-signal of high-resolution MRI in distal ulnar nerve branches at the wrist as diagnostic sign of guyon's-canal-syndrome (GCS).

MATERIALS AND

METHODS

11 GCS patients confirmed by clinical/electrophysiological findings, and 20 wrists from 11 asymptomatic volunteers were prospectively included to undergo the following protocol: axial T2-weighted-fat-suppressed and T1-weighted-turbo-spin-echo-sequences (3T-MR-scanner, Magnetom/Verio/Siemens). Patients were examined in prone position with the arm extended and wrist placed in an 8-channel surface-array-coil. Nerve T2-signal was evaluated as contrast-to-noise-ratios (CNR) from proximal-to-distal in ulnar nerve trunk, its superficial/sensory and deep/motor branch. Distal motor-nerve-conduction (distal-motor-latency (dml)) to first dorsal-interosseus (IOD I) and abductor digiti minimi muscles was correlated with T2-signal. Approval by the institutional review-board and written informed consent was given by all participants.

RESULTS

In GCS, mean nerve T2-signal was strongly increased within the deep/motor branch (11.7±4.8 vs.controls:-5.3±2.4;p = 0.001) but clearly less and not significantly increased in ulnar nerve trunk (6.8±6.4vs.-7.4±2.5;p = 0.07) and superficial/sensory branch (-2.1±4.9vs.-9.7±2.9;p = 0.08). Median nerve T2-signal did not differ between patients and controls (-9.8±2.5vs.-6.7±4.2;p = 0.45). T2-signal of deep/motor branch correlated strongly with motor-conduction-velocity to IOD I in non-linear fashion (R(2) = -0.8;p<0.001). ROC-analysis revealed increased nerve T2-signal of the deep/motor branch to be a sign of excellent diagnostic performance (area-under-the-curve 0.94, 95% CI: 0.85-1.00; specificity 90%, sensitivity 89.5%).

CONCLUSIONS

Nerve T2-signal increase of distal ulnar nerve branches and in particular of the deep/motor branch is highly accurate for the diagnostic determination of GCS. Furthermore, for the first time it was found in nerve entrapment injury that T2-signal strongly correlates with electrical-conduction-velocity.

Для цитирования: Kollmer Jennifer, Bäumer Philipp, Milford David, Dombert Thomas, Staub Frank, Bendszus Martin, Pham Mirko. T2-signal of ulnar nerve branches at the wrist in guyon's canal syndrome.. PloS one. 2012. DOI: 10.1371/journal.pone.0047295.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.