Factors associated with extubation failure in very low birth weight infants: a cohort study in the northeast Brazil.

Teixeira Raphaela Farias, Costa Cinthia Maria, Maria de Abreu Catarina, Lessa Cicero Amsterdan, Carvalho Aline Carla, Kassar Samir Buainain, Barreto Ikaro Daniel, Gurgel Ricardo Queiroz, Medeiros Andrea Monteiro

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Identifying and understanding the main risk factors associated with extubation failure of very low birthweight (VLBW) infants in different populations can subsequently help in establishing better criteria while taking decision of extubation. The aim of the study was to identify factors associated with extubation failure in VLBW infants.

METHODS

A cohort study of VLBW infants who underwent their first extubation between April 2018 and December 2019 in a Neonatal Intensive Care Unit, Alagoas, Brazil, were included in this study. Extubation failure was defined as reintubation within seven days of extubation. Relative risks of predictive variables different between the extubation success group (ES) and extubation failure group (EF) were estimated with a robust Poisson regression model.

RESULTS

Out of the 112 infants included, 26 (23%) cases exhibited extubation failure. Extremely low birth weight (RR 2.55, 95% CI 1.07, 6.06), mechanical ventilation duration for first extubation greater than seven days (RR 2.66, 95% CI 1.10, 6.45), vaginal delivery (RR 2.07, 95% CI 1.03, 4.18) and maternal chorioamnionitis (RR 4.89, 95% CI 1.26-18.98) remained independently associated with extubation failure. EF had a significant greater need for respiratory support, longer oxygen therapy duration, more bronchopulmonary dysplasia (BPD) and longer length of hospital stay, even when adjusted for confounding variables.

CONCLUSIONS

Extremely low birth weight infants needing mechanical ventilation, wherein the duration for first extubation was longer than seven days, with vaginal delivery and maternal chorioamnionitis failed more frequently at the first attempt of extubation. And this failure increased the risk of BPD and the length of hospital stay.

Для цитирования: Teixeira Raphaela Farias, Costa Cinthia Maria, Maria de Abreu Catarina, Lessa Cicero Amsterdan, Carvalho Aline Carla, Kassar Samir Buainain, Barreto Ikaro Daniel, Gurgel Ricardo Queiroz, Medeiros Andrea Monteiro. Factors associated with extubation failure in very low birth weight infants: a cohort study in the northeast Brazil.. Journal of perinatal medicine. 2020. DOI: 10.1515/jpm-2020-0313.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.