DOI 10.1016/j.athoracsur.2018.07.055
Left Ventricular Function After Repair of Totally Anomalous Pulmonary Venous Connection.
Аннотация
BACKGROUND
Poor left ventricular (LV) growth and diastolic dysfunction long after simple total anomalous pulmonary venous connection (TAPVC) repair has been well documented and is believed to originate from insufficient preoperative volume preload. The objective of the study was to confirm these findings.
METHODS
Of 61 patients undergoing simple TAPVC repair between 1996 and 2016, 42 patients undergoing postoperative catheter examinations were enrolled. The mean age at the time of repair was 39 ± 117 days. Postoperative catheter examinations were conducted at a mean duration of 1.1 years after the repair. LV end-diastolic volume (LVEDV) was calculated by biplane cineangiography with the use of Simpson's method as a Graham modification.
RESULTS
LV ejection fraction, LV end-diastolic pressure (LVEDP), and cardiac index were 72% ± 5%, 10.3 ± 2.7 mm Hg, and 4.0 ± 0.7 L •·min-1 • m-2, respectively. LVEDV was 102% ± 16% of the predictive normal value, and it strongly correlated with the predictive normal value of LV end-diastolic diameter (LVEDd) calculated by two-dimensional echocardiography (R2 = 0.29, p = 0.005). LVEDd maintained a normal range thereafter during the entire follow-up period. LVEDP correlated linearly with age at the time of TAPVC repair (R2 = 0.18, p = 0.007) but not with LVEDV (p = 0.67).
CONCLUSIONS
LV size maintained a normal range after the repair of simple TAPVC. High LVEDP was frequently observed a year after repair; it did not correlate with LV size but had a strong negative correlation with age at the time of repair.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.