MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2147/dhps.s507740

Медицинская библиотека · Drug, healthcare and patient safety · 2025

Establishing of a National Diagnostic Reference Level for Radiation Dose in Digital Paediatric Pelvic X-Rays in Jordan: A Multicenter Retrospective Study.

AlHawadi Malak, Ayasrah Mohammad

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Paediatric pelvic X-rays are essential for diagnosing injuries and developmental abnormalities but pose radiation risks to sensitive children. Dose Reference Levels (DRLs) play a critical role in optimising radiographic procedures, ensuring both safety and high-quality imaging.

OBJECTIVE

This research aimed to establish a National Dose Reference Level (NDRL) for digital paediatric pelvic X-rays in Jordan to optimise radiation doses, improve diagnostic accuracy, and minimise risks.

METHODS

A Multicenter retrospective analysis was performed on paediatric Anterior-Posterior (AP) digital pelvic X-rays from various 12 Jordanian healthcare institutions. Parameters including Kilovoltage peak (kVp), milli Ampere second (mAs), and Focal to Skin Distance (FSD) were collected. Entrance Surface Dose (ESD) was indirectly calculated following international guidelines.

RESULTS

The study analysed 1,674 paediatric pelvic X-rays, finding a mean ESD of 0.69 milli-Gray (mGy). The 75th percentile ESD, or (DRL), was 0.612 mGy overall, with age-specific DRLs of 0.265 mGy (0 to <1 year), 0.382 mGy (1 to <5 years), 0.704 mGy (5 to <10 years), and 0.995 mGy (10 to ≤15 years).

CONCLUSION

The study revealed age-dependent variations and notable disparities in radiation doses among various healthcare institutions in Jordan. Establishing the NDRL of 0.612 mGy provides a benchmark for dose optimisation and aligns Jordan's practices with international standards. The findings can guide national radiation protection policies and clinical guidelines, enhance paediatric imaging practices, and minimise unnecessary radiation exposure.

Для цитирования: AlHawadi Malak, Ayasrah Mohammad. Establishing of a National Diagnostic Reference Level for Radiation Dose in Digital Paediatric Pelvic X-Rays in Jordan: A Multicenter Retrospective Study.. Drug, healthcare and patient safety. 2025. DOI: 10.2147/dhps.s507740.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.