Медицинская библиотека · Abdominal radiology (New York) · 2025

Relationship between spleen volume and diameter for assessment of response to treatment on CT in patients with hematologic malignancies enrolled in clinical trials.

Hasenstab Kyle A, Lu Jie, Leong Lambert T, Bossard Emily, Pylarinou-Sinclair Evye, Devi Karthika, Cunha Guilherme M

СтатьяПеревод в очереди

Аннотация

PURPOSE: Investigate spleen diameter (d) and volume (v) relationship in patients with hematologic malignancies (HM) by determining volumetric thresholds that best correlate to established diameter thresholds for assessing response to treatment. Exploratorily, interrogate the impact of volumetric measurements in response categories and as a predictor of response.

METHODS

Secondary analysis of prospectively collected clinical trial data of 382 patients with HM. Spleen diameters were computed following Lugano criteria and volumes using deep learning segmentation. d and v relationship was estimated using power regression model, volumetric thresholds ([Formula: see text]) for treatment response estimated; threshold search to determine percentual change ([Formula: see text] and minimum volumetric increase ([Formula: see text]) that maximize agreement with Lugano criteria performed. Spleen diameter and volume predictive performance for clinical response investigated using random forest model.

RESULTS

[Formula: see text] describes the relationship between spleen diameter and volume. [Formula: see text] for splenomegaly was 546 cm³. [Formula: see text], [Formula: see text], and [Formula: see text] for assessing response resulting in highest agreement with Lugano criteria were 570 cm3, 73%, and 170 cm3, respectively. Predictive performance for response between diameter and volume were not significantly different (P=0.78).

CONCLUSION

This study provides empirical spleen volume threshold and percentual changes that best correlate with diameter thresholds, i.e., Lugano criteria, for assessment of response to treatment in patients with HM. In our dataset use of spleen volumetric thresholds versus diameter thresholds resulted in similar response assessment categories and did not signal differences in predictive values for response.

Для цитирования: Hasenstab Kyle A, Lu Jie, Leong Lambert T, Bossard Emily, Pylarinou-Sinclair Evye, Devi Karthika, Cunha Guilherme M. Relationship between spleen volume and diameter for assessment of response to treatment on CT in patients with hematologic malignancies enrolled in clinical trials.. Abdominal radiology (New York). 2025. DOI: 10.1007/s00261-025-05030-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.