MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.crad.2026.107405

Медицинская библиотека · Clinical radiology · 2026

Semiautomated magnetic resonance imaging-based breast density measurement from routine sequences: comparison with mammography.

Takatsu Y, Shimizu M, Nakamura T, Sagawa H, Takano K, Harada S, Yamashiro T, Kobayashi S, Miyati T, Kumasaka S

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

AIM: High breast density increases breast cancer risk and decreases mammographic sensitivity, yet prior magnetic resonance imaging (MRI)-based density assessments have relied on specialized sequences or vendor-dependent software. This study aimed to evaluate a semiautomated workflow for MRI-based breast density measurement using routinely acquired MRI sequences and compare its diagnostic performance and concordance with visual and software-based mammographic classifications.

MATERIALS AND

METHODS

In this single-center retrospective study, we analyzed 113 women (mean age: 60.8 ± 13.6 years) who underwent both breast MRI and mammography. The contralateral, normal breast was evaluated. MRI was performed using a 3.0-T scanner with a 3D T1-weighted gradient-echo sequence. Breast and fibroglandular tissues were segmented using a deep learning-assisted automated method with manual correction. Statistical analyses included correlation analysis, Bland-Altman analysis, and receiver operating characteristic (ROC) analysis.

RESULTS

MRI-based breast density showed a strong correlation with mammographic density (r = 0.781, P < 0.001), although MRI values were on average 27.7% lower. The area under the ROC curve for detecting high-density breasts was 0.869 for MRI and 0.799 for mammography (P = 0.085).

CONCLUSIONS

Semiautomated MRI-based breast density assessment using routine MRI sequences allowed for quantitative evaluation of breast composition without using ionizing radiation. MRI-based density measurements exhibited classification performance comparable to mammographic assessment. These findings support the potential utility of MRI for quantitative breast density evaluation, although further validation and workflow standardization are required before broader clinical application.

Для цитирования: Takatsu Y, Shimizu M, Nakamura T, Sagawa H, Takano K, Harada S, Yamashiro T, Kobayashi S, Miyati T, Kumasaka S. Semiautomated magnetic resonance imaging-based breast density measurement from routine sequences: comparison with mammography.. Clinical radiology. 2026. DOI: 10.1016/j.crad.2026.107405.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.