MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jdent.2026.106613

Медицинская библиотека · Journal of dentistry · 2026

Trueness of artificial intelligence-driven CBCT tooth segmentation: A comparative validation ex vivo pilot study.

Reymus Marcel, Diegritz Christian, Walter Elias, Schwendicke Falk, Waschke Jens, Kugelmann Daniela, Kessler Andreas, Werner Nils

СтатьяСравнительное исследованиеВалидационное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

To evaluate and compare the trueness of four commercial AI-driven segmentation tools (Diagnocat, Relu, CephX, CoDiagnostiX) and one open-source software (3D Slicer with DentalSegmentator) for dental cone-beam computed tomography (CBCT) segmentation using extracted human teeth as physical ground truth reference.

METHODS

Ten single-rooted teeth from two formaldehyde-fixed human donor heads were scanned using high-resolution CBCT (90 µm voxel size). Following CBCT acquisition, the teeth were extracted and digitized using an intraoral scanner (TRIOS 4) to create ground-truth reference models. DICOM datasets were processed by each segmentation software. 3D models were registered to reference scans of extracted teeth using landmark-based alignment followed by iterative closest point refinement. Surface-to-surface distances were calculated, including Hausdorff distance, root mean square distance (RMSD), mean absolute distance (MAD), median distance, and 95th percentile distance.

RESULTS

Significant differences were observed between segmentation tools for all metrics (Friedman test, p < 0.001). Relu demonstrated the highest trueness with Mean Distance of 0.11 mm [0.09-0.11], followed by Diagnocat 0.10 mm [0.09-0.13], CoDiagnostiX 0.14 mm [0.12-0.16], 3D Slicer 0.13 mm [0.12-0.15], and CephX 0.24 mm [0.21-0.25]. Post-hoc analysis revealed significant differences between top-performing (Relu, Diagnocat) and lower-performing tools (CephX). 3D Slicer showed performance similar to that of commercial solutions.

CONCLUSIONS

Relu and Diagnocat achieved the highest trueness for CBCT tooth segmentation when validated against physical specimens. All tested tools demonstrated clinically acceptable trueness for most applications, though performance varied considerably between platforms.

CLINICAL SIGNIFICANCE: This pilot study provides preliminary comparative data on AI segmentation tool trueness that may inform future larger-scale validation studies. The findings suggest performance differences between platforms that warrant further investigation before definitive clinical recommendations can be made.

Для цитирования: Reymus Marcel, Diegritz Christian, Walter Elias, Schwendicke Falk, Waschke Jens, Kugelmann Daniela, Kessler Andreas, Werner Nils. Trueness of artificial intelligence-driven CBCT tooth segmentation: A comparative validation ex vivo pilot study.. Journal of dentistry. 2026. DOI: 10.1016/j.jdent.2026.106613.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.