MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/hed.20996

Медицинская библиотека · Head & neck · 2009

Place and value of the recurrent laryngeal nerve (RLN) palpatory method in preventing RLN palsy during thyroid surgery.

Altorjay Aron, Tihanyi Zoltán, Luka Ferenc, Juhász Arpád, Bencsik Zsuzsanna, Rüll Miklós, Kecskés Gábor, Paál Balázs

СтатьяПеревод в очереди

Аннотация

BACKGROUND

In recent years, certain publications have appeared confirming that intraoperative palpation of the recurrent laryngeal nerve (RLN) is a very reliable method.

METHOD: The characteristics of the surgical anatomy of 1023 RLN have been summarized on the basis of intraoperative palpability, running down, branching variations, thickness, and laryngeal entry site.

RESULTS

Palpation was helpful in 81.4% (833/1023), proved false positive in 8.2% (84/1023), and in 10.4% (106/1023) it was of no help in the exact localization. Definitive RLN palsy was experienced in 0.78% of all cases (8/1023), while transient paresis was encountered in 1.2% (12/1023). Only a moderately strong stochastic correlation could be found between RLN palsies and those nerves which were nonpalpable and atypical, which showed the joint occurrence of being both thinner than normal and branching already before the plane of the inferior thyroid artery (Cramer's associate coefficient, C = 0.383).

CONCLUSION

Palpation alone cannot substitute visualization and proper surgical dissection of the nerve.

Для цитирования: Altorjay Aron, Tihanyi Zoltán, Luka Ferenc, Juhász Arpád, Bencsik Zsuzsanna, Rüll Miklós, Kecskés Gábor, Paál Balázs. Place and value of the recurrent laryngeal nerve (RLN) palpatory method in preventing RLN palsy during thyroid surgery.. Head & neck. 2009. DOI: 10.1002/hed.20996.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.