MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/epi.16431

Медицинская библиотека · Epilepsia · 2020

Seizures induce obstructive apnea in DBA/2J audiogenic seizure-prone mice: Lifesaving impact of tracheal implants.

Irizarry Rachel, Sukato Daniel, Kollmar Richard, Schild Samuel, Silverman Joshua, Sundaram Krishnamurthi, Stephenson Stacy, Stewart Mark

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The mechanism(s) for sudden death in epilepsy (SUDEP) remain(s) unknown, but seizure spread to brainstem areas serving autonomic and respiratory function is critical. In a rat model, we established a mechanism for SUDEP that involves seizure-induced laryngospasm and obstructive apnea lasting until respiratory arrest. We hypothesized that DBA/2J mice, which display lethal audiogenic seizures, would be protected from death by implanting a tracheal T-tube as a surrogate airway. In a 2 × 2 design, mice were implanted with either open or closed tracheal T-tubes and treated with either low-dose ketamine/xylazine to moderate thoracic spasm during the tonic seizure phase or no drug. Animals receiving both treatments had the highest survival rate, followed by animals receiving the open tube without ketamine/xylazine. The odds ratio for survival was >20 higher with an open T-tube (odds ratio = 24.14). The impact of open tracheal tubes indicates that the mechanism of death in DBA/2J mice involves seizure-induced upper airway obstruction until respiratory arrest. These results, our rat work, and our demonstration of inspiratory effort-based electromyographic signals and electrocardiographic abnormalities in rats and humans suggest that seizure-induced laryngospasm and obstructive apnea directly link seizure activity to respiratory arrest in these sudden death examples.

Для цитирования: Irizarry Rachel, Sukato Daniel, Kollmar Richard, Schild Samuel, Silverman Joshua, Sundaram Krishnamurthi, Stephenson Stacy, Stewart Mark. Seizures induce obstructive apnea in DBA/2J audiogenic seizure-prone mice: Lifesaving impact of tracheal implants.. Epilepsia. 2020. DOI: 10.1111/epi.16431.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.