Impact of CoreValve size selection based on multi-slice computed tomography on paravalvular leak after transcatheter aortic valve implantation.

Chodór Piotr, Wilczek Krzysztof, Przybylski Roman, Głowacki Jan, Kukulski Tomasz, Streb Witold, Niklewski Tomasz, Honisz Grzegorz, Trzeciak Przemysław, Podolecki Tomasz, Włoch Łukasz, Zembala Marian, Kalarus Zbigniew

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Paravalvular leak (PVL) has significant impact on long-term outcomes in patients after transcatheter aortic valve implantation (TAVI). This study sought to determine whether multi-slice computed tomography (MSCT)-guided valve selection reduces PVL after CoreValve implantation.

METHODS

The analysis encompassed 69 patients implanted with CoreValve and were divided into two groups. In Group I (30 patients), valve selection was based on standard procedures, in Group II (39 patients), on MSCT measurements. Paravalvular leak was assessed with angiography and echocardiography.

RESULTS

Multi-slice computed tomography results influenced a change of decision as to the size of the implanted valve in 12 (30.9%) patients in Group II and would have caused the decision to change in 9 (37.5%) patients in Group I. The degree of oversizing in Group I and II was 12.8% ± ± 7.6% vs. 18.6% ± 5.1% (p = 0.0006), respectively. The oversizing among the patients with leak degree of 0-1 and ≥ 2 was 18.1% ± 6.0% and 12.8% ± 7.4% (p = 0.0036). Angiographic assessment indicated post-procedural PVL ≥ 2 in 50% of patients in Group I and 20.5% in Group II (p = 0.01), while echocardiographic assessment indicated the same in 73.3% of patients in Group I and 45.6% in Group II (p = 0.0136). The composite endpoint occurred in 26.6% (8/30) patients in Group I vs. 5.1% (2/39) patients in Group II (p = 0.0118).

CONCLUSIONS

Selecting the CoreValve device based on MSCT resulted in smaller rates of PVL and less frequent composite endpoint. In 1/3 of patients MSCT led to a change of the valve size. The degree of oversizing had a significant impact on PVL.

Для цитирования: Chodór Piotr, Wilczek Krzysztof, Przybylski Roman, Głowacki Jan, Kukulski Tomasz, Streb Witold, Niklewski Tomasz, Honisz Grzegorz, Trzeciak Przemysław, Podolecki Tomasz, Włoch Łukasz, Zembala Marian, Kalarus Zbigniew. Impact of CoreValve size selection based on multi-slice computed tomography on paravalvular leak after transcatheter aortic valve implantation.. Cardiology journal. 2017. DOI: 10.5603/cj.a2017.0014.