Influence of an EDTA-based catheter lock solution on blood discard volume in PICC.

Rajdl Daniel, Maxová Klára Kabátová, Chovancová Jana, Vodičková Petra, Bultasová Lenka, Fejt Martin, Prokop Pavel, Koldušková Klára, Kletečka Jakub

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Vascular access devices (VADs) are increasingly used for blood sampling, yet optimal discard volumes remain uncertain, particularly when EDTA-based lock solutions are used.

OBJECTIVE

To evaluate whether discarding 1 mL is sufficient for reliable laboratory testing after use of 4% tetrasodium EDTA catheter lock solution (Kitelock™) in PICC.

METHODS

In a prospective study, 10 patients with single-lumen peripherally inserted central catheters (polyurethane, 4F, open-ended) underwent blood sampling after flushing the catheter and discarding 1 mL, corresponding to approximately two dead spaces for the shortened catheters used. Five consecutive tubes were analyzed per sample type (biochemistry, hematology, coagulation). Agreement with the reference tube (tube 5) was assessed using Bland-Altman plots, clinically acceptable intervals (CAI), intraclass correlation coefficient (ICC), and Lin's concordance correlation coefficient (CCC).

RESULTS

In the first tube, several analytes reached 10/10 comparisons within the CAI (urea, sodium, potassium, calcium, magnesium, alkaline phosphatase, erythrocytes, hematocrit, MCV, leucocytes, thrombin time). Others showed 9/10 comparisons (total protein, albumin, chloride, hemoglobin, thrombocytes, APTT, prothrombin time, fibrinogen). Only creatinine reached 8/10.

CONCLUSIONS

Discarding 1 mL appeared sufficient for reliable testing after Kitelock™ use in our cohort, but confirmation in larger studies is warranted.

Для цитирования: Rajdl Daniel, Maxová Klára Kabátová, Chovancová Jana, Vodičková Petra, Bultasová Lenka, Fejt Martin, Prokop Pavel, Koldušková Klára, Kletečka Jakub. Influence of an EDTA-based catheter lock solution on blood discard volume in PICC.. The journal of vascular access. 2025. DOI: 10.1177/11297298251403726.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.