MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mat.0000000000001451

Медицинская библиотека · ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2022

De Novo Human Leukocyte Antigen Allosensitization in Heartmate 3 Versus Heartmate II Left Ventricular Assist Device Recipients.

Jain Rashmi, Habal Marlena V, Clerkin Kevin J, Latif Farhana, Restaino Susan W, Zorn Emmanuel, Takeda Koji, Naka Yoshifumi, Yuzefpolskaya Melana, Farr Maryjane A, Colombo Paolo C, Sayer Gabriel T, Uriel Nir, Topkara Veli K

СтатьяПеревод в очереди

Аннотация

Left ventricular assist devices (LVADs) are associated with the development of antihuman leukocyte antigen (HLA) antibodies, which can create a challenge for future transplantation in these patients. The differential effects of Heartmate 3 (HM3) versus Heartmate II (HMII) on de novo HLA allosensitization remain unknown. Patients who underwent HMII or HM3 implantation and had no prior HLA antibodies by solid-phase assay (Luminex) testing were included in this study. Complement-dependent cytotoxicity (CDC) panel reactive antibody (PRA) levels and Luminex antibody profiles were followed until cardiac transplantation, device explantation, or death. Electronic medical records were reviewed to examine posttransplant outcomes. Thirty-eight HM3 and 34 HMII patients with complete data were followed for 1.5 ± 1.1 years on device support. HM3 and HMII groups had similar age at implant, female gender, ischemic heart failure etiology, bridge strategy at implant, as well as intraoperative and postoperative transfusion requirements. 39.5% of HM3 and 47.1% of HMII patients developed detectable HLA antibodies by Luminex testing (p = 0.516). Development of high-level (mean fluorescence intensity >10,000) antibodies was significantly lower in HM3 than HMII patients (5.3 vs. 20.6%, p = 0.049). CDC PRA testing showed fewer HM3 patients with a positive result (PRA > 0%) than HMII patients (39.4 vs. 70.0%, p = 0.015). Among transplanted patients, those who had developed de novo sensitization on LVAD support showed a trend toward incidence of moderate to severe grade rejection compared with unsensitized patients (23.8 vs. 4.8%, p = 0.078). HM3 is associated with lower risk of de novo HLA sensitization compared with HMII.

Для цитирования: Jain Rashmi, Habal Marlena V, Clerkin Kevin J, Latif Farhana, Restaino Susan W, Zorn Emmanuel, Takeda Koji, Naka Yoshifumi, Yuzefpolskaya Melana, Farr Maryjane A, Colombo Paolo C, Sayer Gabriel T, Uriel Nir, Topkara Veli K. De Novo Human Leukocyte Antigen Allosensitization in Heartmate 3 Versus Heartmate II Left Ventricular Assist Device Recipients.. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2022. DOI: 10.1097/mat.0000000000001451.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.