Medical comorbidities and orbital implant exposure.
Аннотация
PURPOSE: To investigate medical conditions and systemic therapies associated with orbital implant exposure in patients with anophthalmic sockets.
METHODS
Retrospective review of patients who underwent enucleation or evisceration at a single centre between January 1, 2008 and March 1, 2018. Medical comorbidities, including peripheral or coronary artery disease, rheumatologic conditions, diabetes, malignancy and history of smoking were recorded. Use of immunomodulatory and anticoagulation therapy at the time of eye removal was noted. Patients were divided into two groups-those with implant exposure and those without. Univariate and multivariate analysis was used to compare groups.
RESULTS
Two hundred and twenty-nine patients underwent eye removal surgery over a ten-year period. Implant exposure was seen in 20 (8.7%) patients. Univariate analysis revealed a statistically significant difference between groups in rates of smoking, malignancy, and immunomodulatory therapy at the time of surgery. A history of smoking (HR = 11.72; 95% CI: 2.95, 46.53; p = 0.0001) and immunomodulatory therapy (HR = 8.02; 95% CI: 1.96, 32.87; p = 0.004) were independent predictors of exposure. The probability of exposure was 81.2% when all three risk factors were present versus 4.4% when none were present (c-index = 0.737, 95% CI: 0.608, 0.865; p < 0.001). The model was a good fit to the data (Hosmer-Lemeshow goodness-of-fit test p = 0.475).
CONCLUSIONS
Smoking and immunomodulatory therapy were associated with orbital implant exposure in patients with anophthalmic sockets. This is the first report examining medical comorbidities in patients with orbital implant exposure. Understanding the pathophysiology of implant exposure is crucial to preoperative planning and postoperative care.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.