MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/07853890.2026.2668217

Медицинская библиотека · Annals of medicine · 2026

Assay-dependent variability in peptide biomarker quantification: experimental evidence from renalase in chronic kidney disease.

Serwin Natalia, Cecerska-Heryć Elżbieta, Grygorcewicz Bartłomiej, Wiśniewska Magda, Gomółka Aleksandra, Bąk Katarzyna, Cader-Ptak Aleksandra, Wojciuk Bartosz, Lisak Marcin, Opara-Bajerowicz Martyna, Polikowska Aleksandra, Goszka Małgorzata, Serwin Karol, Suwała Mariusz, Fiedorowicz Katarzyna, Ciechanowski Kazimierz, Dołęgowska Barbara

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Renalase is a promising biomarker for kidney disease, but published levels vary widely between studies. We hypothesised that variability in commercial enzyme-linked immunosorbent assays (ELISAs) kits and matrix effects (serum vs plasma) drive these inconsistencies.

METHODS

Paired serum and plasma samples from 56 participants (28 chronic kidney disease (CKD) stages 2-5, 28 healthy controls) were tested using three commercial renalase ELISAs (BTLAB, Cloud-Clone, EIAab). We assessed intra-assay precision, inter-assay agreement (Spearman's rank correlation and Bland-Altman analysis on log10-transformed values), matrix effects, and associations with estimated glomerular filtration rate (eGFR). Diagnostic performance was evaluated by Receiver operating characteristic (ROC) analysis.

RESULTS

Inter-assay renalase concentrations differed markedly (up to orders of magnitude), with weak inter-assay correlations (r ≤ 0.25). Bland-Altman analyses revealed large, systematic biases between kits. Only the BTLAB assay showed consistent serum/plasma agreement, a significant correlation with eGFR (ρ ≈ 0.32-0.42, p < 0.05), and moderate discriminatory performance for CKD in serum (AUC = 0.70) and plasma (AUC = 0.68). Cloud-Clone and EIAab produced divergent results and strong matrix-dependent biases.

CONCLUSIONS

Observed variability among commercial ELISA platforms may compromise comparability between studies. Harmonisation, standardised reference materials, and cross-validation are necessary before renalase assays can be used reliably in clinical practice.

Для цитирования: Serwin Natalia, Cecerska-Heryć Elżbieta, Grygorcewicz Bartłomiej, Wiśniewska Magda, Gomółka Aleksandra, Bąk Katarzyna, Cader-Ptak Aleksandra, Wojciuk Bartosz, Lisak Marcin, Opara-Bajerowicz Martyna, Polikowska Aleksandra, Goszka Małgorzata, Serwin Karol, Suwała Mariusz, Fiedorowicz Katarzyna, Ciechanowski Kazimierz, Dołęgowska Barbara. Assay-dependent variability in peptide biomarker quantification: experimental evidence from renalase in chronic kidney disease.. Annals of medicine. 2026. DOI: 10.1080/07853890.2026.2668217.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.