Comparative Performance of 4 Penicillin-Allergy Prediction Strategies in a Large Cohort.

Ghiordanescu Ileana-Maria, Ciocănea-Teodorescu Iuliana, Molinari Nicolas, Jelen Anais, Al-Ali Omar, Schrijvers Rik, Demoly Pascal, Chiriac Anca Mirela

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

A safe and pragmatic guide for labelling and delabelling patients with suspected penicillin allergy is mandatory.

OBJECTIVE

To compare the performance of 4 penicillin-allergy prediction strategies in a large independent cohort.

METHODS

We conducted a retrospective study for subjects presenting between January 2014 and December 2021 at the University Hospital of Montpellier, with a history of hypersensitivity to penicillins. The outcome targeted by the study was a positive penicillin-allergy test.

RESULTS

Of the 1,884 participants included, 382 (20.3%) had positive penicillin-allergy tests. The ENDA (European Network on Drug Allergy) and Blumenthal strategies yielded relatively high sensitivities and low specificities and, by design, did not misclassify any positive subjects with severe index reactions. The PEN-FAST <3 score had a negative predictive value of 90% (95% confidence interval [95% CI] 88%-91%), with a sensitivity of 66% (95% CI 62%-71%) and a specificity of 73% (95% CI 71%-75%), and incorrectly delabelled 18 subjects with anaphylaxis and 15 with other severe nonimmediate reactions. For the adapted Chiriac score, the specificity corresponding to 66% sensitivity was 73% (95% CI 70%-75%). Conversely, at a 73% specificity threshold, the sensitivity was 65% (95% CI, 61%-70%). Attempts to improve these prediction algorithms did not substantially enhance performance.

CONCLUSIONS

The ENDA and Blumenthal strategies are safe for high-risk subjects, but their delabelling effectiveness is limited, leading to unnecessary avoidance. Conversely, the PEN-FAST and Chiriac scores are performant in delabelling, but more frequently misclassify high-risk subjects with positive penicillin-allergy tests. Selection of the most appropriate tool requires careful consideration of the target population and the desired goal.

Для цитирования: Ghiordanescu Ileana-Maria, Ciocănea-Teodorescu Iuliana, Molinari Nicolas, Jelen Anais, Al-Ali Omar, Schrijvers Rik, Demoly Pascal, Chiriac Anca Mirela. Comparative Performance of 4 Penicillin-Allergy Prediction Strategies in a Large Cohort.. The journal of allergy and clinical immunology. In practice. 2024. DOI: 10.1016/j.jaip.2024.07.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.