Journal of paediatrics and child health · 2016
Does continuous positive airway pressure for extubation in congenital tracheoesophageal fistula increase the risk of anastomotic leak? A retrospective cohort study.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Shah Piyush S, Gera Parshotam, Gollow Ian J, Rao Shripada C
Аннотация
AIM: Immediate post-operative care of tracheoesophageal fistula (TEF) and oesophageal atresia (EA) requires mechanical ventilation. Early extubation is preferred, but subsequent respiratory distress may warrant re-intubation. Continuous positive airway pressure (CPAP) is a well-established modality to prevent extubation failures in preterm infants. However, it is not favoured in TEF/EA, because of the theoretical risk of oesophageal anastomotic leak (AL). The aim of this study was to find out if post-extubation CPAP is associated with increased risk of AL.
METHODS: Retrospective cohort study (2007-2014).
RESULTS: Fifty-one infants underwent primary repair in the newborn period. Median age at surgery was 24 h (interquartile range: 12, 24). In the post-extubation period, 10 received CPAP, whereas 41 did not. The median post-operative day at the commencement of CPAP was 2.5 days (interquartile range: 1, 6 days). Zero out of 10 in the CPAP group and 4/41 in the 'no CPAP' group developed AL on routine post-operative contrast studies (P = 0.57). Zero out of 10 in the CPAP group and 1/41 in the 'no CPAP group' developed recurrence of TEF necessitating re-surgery (P = 1.00). The neonate with recurrent fistula also had coarctation of aorta and needed protracted hospitalisation of 6 months, mainly because of the recurrence of TEF.
CONCLUSION: The use of CPAP in the immediate post-extubation period after corrective surgery for TEF/EA appears to be safe and may not be associated with increased risk of AL or recurrence of the fistula. Information from other centres, surveys and large databases is needed to define the benefits and risks of use of CPAP in these infants.
METHODS: Retrospective cohort study (2007-2014).
RESULTS: Fifty-one infants underwent primary repair in the newborn period. Median age at surgery was 24 h (interquartile range: 12, 24). In the post-extubation period, 10 received CPAP, whereas 41 did not. The median post-operative day at the commencement of CPAP was 2.5 days (interquartile range: 1, 6 days). Zero out of 10 in the CPAP group and 4/41 in the 'no CPAP' group developed AL on routine post-operative contrast studies (P = 0.57). Zero out of 10 in the CPAP group and 1/41 in the 'no CPAP group' developed recurrence of TEF necessitating re-surgery (P = 1.00). The neonate with recurrent fistula also had coarctation of aorta and needed protracted hospitalisation of 6 months, mainly because of the recurrence of TEF.
CONCLUSION: The use of CPAP in the immediate post-extubation period after corrective surgery for TEF/EA appears to be safe and may not be associated with increased risk of AL or recurrence of the fistula. Information from other centres, surveys and large databases is needed to define the benefits and risks of use of CPAP in these infants.