MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4314/ahs.v25i3.8

Медицинская библиотека · African health sciences · 2025

Assessment of some hematologic markers of Systemic Inflammatory Response (SIR) as eliable biomarkers in detecting preeclampsia; a comparative cross-sectional study in Enugu, Nigeria.

Nwagha Theresa Ukamaka, Okoye Helen Chioma, Enebe Joseph Tochukwu, Izuka Emmanuel Obiora, Ekwuazi Kingsley Emeka, Onyebuchukwu Chiamaka Queenet, Obi Samuel Nnamdi, Nwagha Uchenna Ifeanyi

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Systemic inflammatory response (SIR) occurs in normal pregnancy and is exacerbated in pre-eclampsia (PE). Most markers of SIR are expensive to measure, require trained personnel, and thus are limited for routine application in resource-limited settings. Thus, we aim to determine the clinical utility of hematologic markers of systemic inflammatory response in Preeclampsia in a resource limited setting.

METHODS

A cross-sectional comparative study was conducted in Enugu from April to October 2021. Forty-five women with pre-eclampsia (PE) and 45 matched normotensive (NT) pregnant women were recruited. Hematological markers of systemic inflammatory response (red cell distribution width (RDW), neutrophil-lymphocyte ratio (NLR), platelet lymphocyte ratio (PLR), monocyte lymphocyte ratio (MLR), and platelet indices) were measured using the automated Mythic 22 Orphee hematology analyzer. Statistical analysis was by student T-test, receiver operating characteristics (ROC) curve, and Pearson correlation test. A P value of < 0.05 was considered significant.

RESULTS

The age difference between the groups was not significant (P = 0.76). Pregnant women with preeclampsia had significantly higher RDWS (P=0.02) and NLR (P <0.001) but a significantly lower PLR (P =0.04). The NLR had the largest area under the ROC curve (AUC 0.82, 95% CI (0.74-0.906, P <0.001), cut-off >2.56, sensitivity 71.1%; specificity 22.2%) followed by MLR (AUC 0.68, 95% CI (0.58-0.80, P =0.002) cut-off >0.18, sensitivity 64.4%; specificity: 28.9 %;).

CONCLUSION

The NLR and MLR were good and affordable biomarkers of Systemic Inflammatory response (SIR) in Preeclampsia, thus possible alternative in resource-limited settings.

Для цитирования: Nwagha Theresa Ukamaka, Okoye Helen Chioma, Enebe Joseph Tochukwu, Izuka Emmanuel Obiora, Ekwuazi Kingsley Emeka, Onyebuchukwu Chiamaka Queenet, Obi Samuel Nnamdi, Nwagha Uchenna Ifeanyi. Assessment of some hematologic markers of Systemic Inflammatory Response (SIR) as eliable biomarkers in detecting preeclampsia; a comparative cross-sectional study in Enugu, Nigeria.. African health sciences. 2025. DOI: 10.4314/ahs.v25i3.8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.