Reliability of comprehensive echocardiography evaluation of patent ductus arteriosus among extremely preterm neonates across a national network: A prospective observational study.

Weisz Dany E, Thomas Laura, Ye Xiang Y, Mertens Luc, Lapointe Anie, Villeneuve Andréanne, Altit Gabriel, Lalitha Renjini, Ben Fadel Nadya, Jacob George, Louis Deepak, Bhattacharya Soume, Soraisham Amuchou, Hébert Audrey, Mitra Souvik, Hyderi Abbas, Ting Joseph Y, Castaldo Michael, Surak Aimann, Deshpande Poorva, Elsayed Yasser, Jasani Bonny, Nissimov Sagee, Zhu Faith, Shah Prakesh, Jain Amish

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

BackgroundPrior studies on the reliability of targeted neonatal echocardiography (TNE) among extremely low gestational age neonates (ELGANs) with a patent ductus arteriosus (PDA) have been limited to evaluation of pre-defined images by a small set of study observers. The objective of this study was to investigate the interobserver reliability of comprehensive echocardiography measures of PDA size/shunt volume and ventricular performance among TNE-neonatologists in a large national network.MethodsWe conducted a prospective observational study. TNEs performed for the evaluation of PDA among ELGANs were analyzed by TNE-neonatologists from the Canadian TNE Consortium. Analyses were conducted via an interactive videoconferencing platform offering full remote control to the review software. Reliability for continuous measures was evaluated using the intraclass correlation coefficient (ICC) and coefficient of variation. The kappa statistic was used to evaluate the interobserver reliability of categorical parameters.ResultsReliability was excellent among indices of PDA size and gradient (ICC≥0.91) and good-to-excellent among most indices of left ventricular (LV) size and output (ICC≥0.79, except for LV end-systolic volume and left atrium to aortic root ratio). There was substantial to near-complete agreement on PDA shunt direction and diastolic flow abnormalities in the abdominal aorta and systemic arteries (kappa ≥0.78). However, reliability for measures of LV systolic and diastolic performance was variable with ICC range 0.21-0.95, though with low coefficient of variation (<15%).ConclusionsInterobserver reliability for most TNE measures of PDA size, gradient, shunt volume, and LV dimensions and function is good-to-excellent, supporting the validity of incorporating these indices in prospective multicenter research.

Для цитирования: Weisz Dany E, Thomas Laura, Ye Xiang Y, Mertens Luc, Lapointe Anie, Villeneuve Andréanne, Altit Gabriel, Lalitha Renjini, Ben Fadel Nadya, Jacob George, Louis Deepak, Bhattacharya Soume, Soraisham Amuchou, Hébert Audrey, Mitra Souvik, Hyderi Abbas, Ting Joseph Y, Castaldo Michael, Surak Aimann, Deshpande Poorva, Elsayed Yasser, Jasani Bonny, Nissimov Sagee, Zhu Faith, Shah Prakesh, Jain Amish. Reliability of comprehensive echocardiography evaluation of patent ductus arteriosus among extremely preterm neonates across a national network: A prospective observational study.. Journal of neonatal-perinatal medicine. 2025. DOI: 10.1177/19345798251349744.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.