Медицинская библиотека · Revista medica del Instituto Mexicano del Seguro Social · 2019

[Risk factors associated with late-onset neonatal sepsis].

Arias-Arellano Santiago, Cáceres-Aucatoma Freud, Geyson Déley, Segarra-Galarza Katy

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

BACKGROUND

Sepsis is one of the main causes of morbidity and mortality in neonates.

OBJECTIVE

To identify the risk factors for neonatal sepsis in a neonatal unit from March to October, 2016.

METHODS

Case-control study. The factors analyzed were: a) neonatal factors such as: type of delivery, sex, birth weight, gestational age, criteria for systemic inflammatory response syndrome, type of sepsis (early or late) and blood culture result; B) invasive methods such as: central catheterization, total parenteral nutrition, umbilical catheterization and mechanical ventilation; C) maternal factors such as: number of prenatal controls, infection during pregnancy, premature rupture of membranes, maternal age and maternal fever. Odds Ratio was used to determine association.

RESULTS

For the development of early-onset sepsis, significant risk factors were: thermodynamic imbalance, tachycardia and maternal fever. With regard to late-onset sepsis, significant associations were found for thermodynamic imbalance, umbilical catheterization, mechanical ventilation and insufficient prenatal care.

CONCLUSIONS

Thermodynamic imbalance, tachycardia, mechanical ventilation, umbilical catheterization, maternal fever, and insufficient prenatal care were the probable risk factors associated with neonatal sepsis.

Для цитирования: Arias-Arellano Santiago, Cáceres-Aucatoma Freud, Geyson Déley, Segarra-Galarza Katy. [Risk factors associated with late-onset neonatal sepsis].. Revista medica del Instituto Mexicano del Seguro Social. 2019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.